Amprobe ACD-15 Pro Manuale d'uso - Pagina 19

Sfoglia online o scarica il pdf Manuale d'uso per Multimetro Amprobe ACD-15 Pro. Amprobe ACD-15 Pro 20. Clamp-on multimeter series

Amprobe ACD-15 Pro Manuale d'uso
Frequency
Voltage Range
6.000V
60.00V
600.0V
Accuracy: 0.5%+4d
Max display: 9999 counts
AC Voltage
RANGE
50Hz / 60Hz
6.000V, 60.00V
600.0V
50Hz ~ 500Hz
6.000V, 60.00V
600.0V
CMRR : >60dB @ DC to 60Hz, Rs=1kΩ
Hi-Z ACV Input Impedance:
5MΩ, 90pF nominal
AutoCheck
Lo-Z ACV input impedance:
TM
Initially 1.6kU, 90pF nominal;
Impedance increases significantly
as display voltage increases from
50V (typical). Typical impedances vs
display voltages for reference are:
15kΩ @ 100V
100kΩ @ 300V
210kΩ @ 600V
ACV Threshold:
AutoCheck
TM
> 2VAC (50/60Hz) nominal
True RMS model ACD-15 TRMS PRO Crest
Factor:
< 1.6 : 1 at full scale & < 3.3 : 1 at half
scale
Sensitivity
Range
(Sine RMS)
4V
10Hz ~ 30kHz
30V
10Hz ~ 1kHz
60V
10Hz ~ 1kHz
Accuracy
1.5% + 5d
2.0% + 5d
2.0% + 5d
2.5% + 5d
Capacitance
RANGE
100.0nF
1000nF,
2)
10.00μF, 100.0μF,
2000μF
1) Accuracies with film capacitor or
better
2) Accuracy below 50nF is not
specified
3) Specified with battery voltage
above 2.8V
(approximately half full battery).
Accuracy decreases gradually to 12%
at low battery warning voltage of
approximately 2.4V
VolTectTM, AC Voltage Detection
Typical Voltage
15V TO 85V
40V TO 130V
60V TO 210V
90V TO 300V
ABOVE 120V
Indication: Bar graph segments
& audible beep tones
proportional to the field
strength
Detection Frequency: 50/60Hz
Detection Antenna: Top side of the
Probe-Contact EF-Detection: For more
precise indication of live wires, use
the Red (+) probe for direct contact
measurements
15
Accuracy
1)
3.5%+5d
3)
Bar Graph
Indication
-
- -
- - -
- - - -
- - - - -
stationary jaw