UNIT INSTALLATION

1) MOUNTING THE UNIT ON THE WALL

• Undo the fastener securing the wall bracket and base at the
back of the unit with cutting pliers.
• If the wall is covered with gypsum
board, we recommend installing a
wooden panel screwed to the wall studs
beforehand for more stability. Then,
screw the bracket to the wall with the
five (5) screws supplied with the unit.
• For a installation directly on a wall stud, screw three (3) screws in
the middle area only.
14
Cut the fastener
Gypsum
Board
Wooden
panel
Wall Stud
Suggested distance
from the floor:
50" (125 cm)
• Lift the head to slide its support onto the wall bracket.
2) CONNECTING THE
DUST INLET
Connect the dust inlet onto the unit
securing it with a collar (do not glue).
UNIT INSTALLATION
15