Draper Access Istruzioni per l'installazione e il funzionamento
Sfoglia online o scarica il pdf Istruzioni per l'installazione e il funzionamento per Schermo di proiezione Draper Access. Draper Access 4. Electric projection screen
Anche per Draper Access: Istruzioni per l'installazione e il funzionamento (2 pagine)
Access Electric Projection Screen by Draper
1 Read instructions through completely before proceeding; keep them
for future reference. Follow instructions carefully. Installation contrary to
instructions invalidates warranty. Care in mounting and correct operation
will mean long and satisfactory service from your Draper screen.
2 Before removing screen from crate, check for damage and to make sure
all parts are included.
3 Allow enough access to remove front cover should fabric become
damaged or should other service be required.
4 Screen should be installed level (using a carpenter's level).
5 Nothing should be fastened to screen dowel or viewing surface.
6 Operating switch(es) is packed separately in screen carton. Do not
discard with packing material.
7 Screen operates on 110-120V, 60 Hz. 1.1 amp current draw.
NOTE: Screen has been thoroughly inspected and tested at factory and
found to be operating properly prior to shipment.
These instructions are meant as a guide only. They do not imply any responsibility on the
part of the manufacturer for improper installation or faulty workmanship at the jobsite.
Hanging Screen
When locating viewing surface and checking clearance for screen operation,
remember surface is centered in the length of the case. Regardless of
mounting method used, the following points apply:
1 Mounting brackets are shipped attached to the case. Engage each bracket
with top of housing as shown below and tighten set screws.
2 Screen should be positively and securely supported so that vibration or
even abusive pulling on viewing surface will not weaken installation.
Please Note: A Hoisting Bracket is included on each end of the case to
aid in overhead installation of the Access case.
3 Installer must insure that fasteners used are of adequate strength and
suitable for the mounting surface chosen. Supporting hardware (chains,
cables,
/
" rods, etc.) must be essentially vertical.
3
8
Typical
Installation
1
1
With typical installation, brackets may be angled to meet installation requirements.
4 Entire bottom of case must be readily accessible
after installation is complete.
5 Front, back and top of case must be straight—
not forced to warp or bow.
6 If case is painted on location, removal of
roller/fabric assembly is recommended
prior to painting. If not removed, slot
on bottom of case should be shielded
to protect viewing surface from paint
splatters/overspray.
7 Do not seal unit in ceiling until electrical
connections have been made and screen has been operated successfully.
Suitable for use in environmental air space in accordance with Section
300-22(c) of the National Electrical Code, and Sections 2-128, 12-010(3) and
12-100 of the Canadian Electrical Code, Part 1, CSA C22.1.
Copyright © 2015 Draper Inc.
Form Access_Inst15
Installation/Operating Instructions
Caution
Figure
"
/
"
7
/
7
8
8
ELECTRICAL
CUTOUT
ELECTRICAL
CUTOUT
Alternate
Installation
(additional set of
brackets required
but not included)
Figure
Shipping
Bracket
brackets before
operating screen.
Printed in U.S.A
Screen operates on 110-120V, 60 hz., 1.1 amp current draw.
Duty Cycle: ON 28 seconds /OFF 4 minutes.
Junction box is located just above the bottom access panel at left end of
screen (standard, right end may be specified).
Remove the bottom access panel for access to the junction box cover. (See
Bottom Access Panel Removal instructions below). Remove two (2) hex head
screws that secure the cover to the junction box to expose the red, black, and
white pigtail leads and the green ground wire per wiring diagram on page 4.
If optional low voltage control is specified and factory installed, please refer to
wiring diagrams on page 4.
Screen is shipped with internal wiring complete and control switch(es) fully
boxed. Wire to connect screen to switch(es) and switch(es) to power supply
should be furnished by installer. Connections should be made in accordance
with attached wiring diagram, and wiring should comply with national and
local electrical codes.
All operating switches should be "off" before power is connected.
Bottom Access Panel Installation/Removal
Bottom access panel is secured to the screen housing by two screws (one on
each end), and is held in the closed position by engagement brackets with ball
detents that snap into case support brackets.
Access case
as seen from
below
Caution: Beware of pinch points at ends of closure
To remove the Access Panel:
1 Remove screws from both ends of screen housing (Fig. 4).
2 Pull down on the access panel until the ball detents on the engagement
bracket have disengaged from the support bracket.
3 Repeat Step 2 for all brackets along the length of the screen housing.
4 The access panel will be free to pivot downward. It will remain attached to
the lower inside edge of the screen housing by several steel hinges.
Remove Screws
from both ends
of Screen Housing
Dowel
Caution: For larger sizes Step 5 requires two people to perform safely.
Remove
5 Press up on access panel and pull toward the front of the screen housing to
shipping
disengage hinges and remove access panel.
To Remove/Install Support Brackets:
Figure
If you encounter any difficulties installing or servicing your Access screen, call your
dealer or Draper, Inc., in Spiceland, Indiana, 765/987-7999 or fax 765/987-7142.
US Patent Nos.
6,137,629; 6,421,175;
6,532,109; 6,816,308;
7,559,707
Electrical Connections
Figure
Bottom Access Panel Door
Access
Panel Door
pivot on Hinges
A
P
CCESS
S
UPPORT
A
TTACHING BRACKETS
Insert pin in top
1
slot and push up
Rotate bracket
2
clockwise to lock
bracket in place
E
NGAGEMENT
B
WITH
ALL
will snap into Access
Panel Support Bracket.
Bottom flange of
Access housing
Figure
ANEL
B
RACKET
B
RACKET
D
ETENT