Draper Silhouette/Series V Istruzioni per l'installazione e il funzionamento - Pagina 5

Sfoglia online o scarica il pdf Istruzioni per l'installazione e il funzionamento per Schermo di proiezione Draper Silhouette/Series V. Draper Silhouette/Series V 5. Electric projection screen
Anche per Draper Silhouette/Series V: Istruzioni per l'installazione e il funzionamento (5 pagine)

Draper Silhouette/Series V Istruzioni per l'installazione e il funzionamento
Silhouette/Series E & V by Draper
Back of wall switch.
Please Note: 5V DC must be
connected to be able to set
limits using the wall switch.
Please Note: Although both
Dry Contact and Data Cable
connections are shown, you
should only use one connec-
tion type per motor.
INTERNAL SCREEN WIRING
White (Common)
Red (Up)
Black (Down)
Green/Yellow
(Motor Ground)
To
110-120 VAC
L1
Line
N
GND
Built-in Video Interface Control
115 VAC supply
Trigger signal
VIC115 (115 VAC, white cord & plug)
VIC12 (12 VDC, brown & orange leads)
Dashed wiring by electrician
ILT Switch-to-Motor—Dry Contacts or Data Cable connection
External LVC-IV - Single or Multiple
Projection Screen Wiring Diagram
Red-to screen (directional)
Brown-to screen (directional)
Yellow-to 110V-220V AC-Hot
Black-to 110V-220V AC-Hot
White -Common to screen & 110V-220V AC Neutral
Green/Yellow (Ground)
Location of key
operated on-off
switch if furnished.
Dashed wiring by electrician
Low voltage wiring by others
Wiring Diagrams for Optional, Built-in Video Interface Control
Junction box at
left end of screen
Internal screen wiring
N
L1
www.draperinc.com
INSERT MOTOR DATA
CABLE HERE
Built-in Low Voltage Control
White (Neutral)
Black (Hot)
Green (Ground)
110v AC supply
(765) 987-7999
Please Note: This Splitter/
Jack is located inside the junc-
tion box of your screen.
Data Cables to switches or
to additional motors can
be plugged into any of the
three open jacks. If this is a
"Case First, Screen Later"
installation, plug the motor
cable into the jack indicated
in the drawing.
Receiver
3 Button Wall Switch
Button
DOWN - Black
COM - White
UP - Red
Electrically Straight
Data Cable to more
LVC-IV modules*
RS232/485
Inputs/Outputs
IR Eye Input
Low Voltage
Trigger
3-28 VDC
Junction box at
left end of screen
Internal screen wiring
N
L1
Dashed wiring
by electrician
Page 5 of 5
Wall Switch
*A maximum of six (6)
LVC-IV modules can be
linked together.
White (Neutral)
Black (Hot)
Green (Ground)