ADVANCED EV ADVENT 8 Manuale - Pagina 18

Sfoglia online o scarica il pdf Manuale per Auto da golf ADVANCED EV ADVENT 8. ADVANCED EV ADVENT 8 19.

ADVANCED EV ADVENT 8 Manuale

Wiring Diagram

AC Curtis Controller
29
THE MALFUNCTION TABLE OF TOYOTA CONTROLLER (48V)
AC Toyota Controller
Preliminary / Confidential
No
Anomalies
Exceptional condition
Temperature
Internal temperature above 80℃
1
anomaly
Internal temperature below -20℃
External
Contator coil short cicuit
connection
2
Forward and backward switches both ON
anomaly
|Phase current value| > 630A
Current
3
When stop, current sensor AD average
anomaly
is beyond 2048±140
Internal
4
Internal temperature sensor short circuit
sensor anomaly
or break
Voltage
Battery voltage above 60V
5
sensor anomaly
Battery voltage below 36V
(※)LED Flash Button Details
1s
0.5s
0.1s
1s
0.5s
0.1s
0.5s
1s
0.5s
0.1s
0.5s
1s
0.5s
0.5s
0.1s
1s
0.5s
0.5s
0.1s
Restoration condition
LED Flash Button
Internal temperature above 75℃
Internal temperature below -15℃
K E Y O F F→O N
K E Y O F F→O N
K E Y O F F→O N
K E Y O F F→O N
Internal temperature sensor values
correctly
Battery voltage below 54V
Battery voltage above 40V
0.1s
0.1s 0.5s 0.1s
0.1s 0.5s
0.1s
0.1s
0.5s
0.1s 0.5s
0.5s 0.1s
0.1s
0.5s
30
0.1s