Bosch Benchmark HBLP451LUC Manuale di servizio - Pagina 20

Sfoglia online o scarica il pdf Manuale di servizio per Forno Bosch Benchmark HBLP451LUC. Bosch Benchmark HBLP451LUC 45. Built-in wall ovens
Anche per Bosch Benchmark HBLP451LUC: Specifiche tecniche (3 pagine), Manuale di installazione (39 pagine), Manuale di installazione (22 pagine)

Bosch Benchmark HBLP451LUC Manuale di servizio
58300000181895 ARA EN A
3. Remove 3 torx-head screws securing the upper hinge to chassis
(A); do not attempt to remove the Phillips-head screw (B).
Figure 20 Removing upper hinge assembly screws
4. Using both hands, carefully lift door slightly upward and outward to
disengage the hanging pins from the upper and lower key hole
cutouts in the cavity front.
1 – Hanging pin
2 – Alignment cam
3 – Cutouts on cavity front for upper/lower hanging pins
Figure 21 Side view of lower hinge and cavity front
Copyright by BSH Home Appliances Corporation
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
A – Three T-20 torx
screws secure upper
hinge to chassis
B – Phillips-head screw
3
1901 Main St ▪ Suite 600 ▪ Irvine, CA 92614
JUNE 2014
Service Manual for Bosch Benchmark Series Built-in Wall Ovens
5. Set the door aside on a protected flat surface.
To re-install the door...
1. Open and align the upper and lower hinges to approximately 135°
open.
2. Hold the door securely with both hands, and position the door on
the front frame of the chassis, guiding the hanging pin on the top
hinge into the keyhole on the front frame.
3. Position the top hinge fully against the front frame, then slide the
top hinge toward the side trim until both hinges rest against the
side trim. (The outermost edge of the hinge will also be flush with
the side of the control panel.)
4. Lift the weight off the hinges and loosely re-install the three torx
screws in the upper hinge (leave one or two turns left on each
screw).
5. Confirm that the upper hinge is parallel with the control panel and
tighten the three torx screws.
Tip: The
sides of
these T-20
screw slots
should be
visible when
the hinges
are properly
aligned.
Figure 22 Hinge position when reinstalling door
6. Confirm that the lower hinge is still in place, and release the door.
Tip: The top
of the hinge
should be
parallel with
the bottom
edge of the
control
panel.
Page 20 of 45
800 944-2904