Bosch Benchmark Series Manuale di servizio - Pagina 29
Sfoglia online o scarica il pdf Manuale di servizio per Forno Bosch Benchmark Series. Bosch Benchmark Series 36. Built-in wall ovens
Anche per Bosch Benchmark Series: Manuale di installazione (32 pagine), Manuale di riferimento rapido (4 pagine), Manuale di servizio (45 pagine), Manuale di istruzioni per l'installazione (40 pagine), Manuale di avvio rapido e di sicurezza (13 pagine)
58300000187895 ARA EN A
10 TROUBLESHOOTING
The information in this section will be helpful when troubleshooting, diagnosing, and resolving faults and other issues affecting the normal operation
of the oven in the range. Please refer to the cooktop Failure Codes and Service Programs in QuickFinder.
10.1
Error Codes
A Service Guide/Wire Diagram that includes error code information is available in QuickFinder and is also packed with
every range. Separate diagrams for the induction cooktops are also packed with each range. Find them in a pouch taped
to the rear vented panel, as shown in Figure 33.
Additional error code information and suggested repair actions can be found in the following table. Note that error codes
which begin with E1 apply specifically to the oven cavity, and those which begin with E2 apply specifically to the
warming drawer.
Error
Description
Code
Wrong module code
E000
(E100/E400 internal errors
reported as E000)
E302
Control module too hot
Copyright by BSH Home Appliances Corporation
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
MAY 2015
Cause/Notes
Control module and user interface are
mismatched. No operation is possible.
Temperature sensor on the control module
detects temperature higher than limit value.
Control turns off heating elements and fan
defaults to high speed. When cavity
temperature lowers to 212°F/100°C, heating
will resume and error will be cleared. (If self-
clean was running, it will be disabled until a
control reset is performed.)
1901 Main St ▪ Suite 600 ▪ Irvine, CA 92614
Service Manual for Bosch Benchmark Series Induction Slide-in Ranges
Figure 33 Location of wire diagrams on the rear vented panel
Suggested Action(s)
Enter correct option code in Service mode.
If cooling fan is not operating...
Check connections to the fan and the
control module (see Small Load Schematic).
If cooling fan is operating...
Check element operation
Check for air obstruction or damaged
upper/lower ventilation trims
Check for stuck relays.
Page 29 of 36
800 944-2904