BDE 2010 Manuale d'uso - Pagina 5

Sfoglia online o scarica il pdf Manuale d'uso per Accessories BDE 2010. BDE 2010 6.

= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
Caution:
Dear customers, our company will charge fees if your operator mistakenly input incorrect internal
parameters below as a result of service.
Chapter 10 Functions (Only for Agent)
Power On, Press Print key once when counting down (before showing 0 weight).
The display shows: pn,Input M+, G/N, TARE as password. Now entering parameter setups.
The display shows " p0 chk ".
Press TARE Key to move down (Circle).
Press ZERO key to select.
Press M+ or MR to move left or right. Press G/N to escape.
Sub
Func.
Func.
P0
SET H
CHK
SET LO
BEEP
P1
AZN 0
REF
0AUTO
0RAGE
0-Tare
SPEED
Zero
P2
MODE
COM
(Not
suitable
out
side of
Taiwan)
BAUD
pr
P3 CAL
DECI
INC
CAP
CAL
COUNT
P4
LOCK
OTH
ANM
P5 unit
Kg/lb
/lb-oz
/tj/ hj
Parameters
Set Hi limit, Press M+ MR to move left or right, Press TARE to add value,
press PRINT to clear value, Press ZERO to confirm.
Set Low limit, Press M+ MR to move left or right, Press TARE to add
value, press PRINT to clear value, Press ZERO to confirm.
Set buzzer mode
no: buzzer off
OK: buzzer on between hi and lo(OK)
ng: buzzer on out of tolerance (NG)
Auto zero tracking: 0.5d, 1d, 2d, 4d
Set zero range: 0%, 2%, 5%, 10%, 20%, 50%, 100%
Manual zero range: 0%, 2%, 4%, 10%, 20%, 50%, 100%
Auto tare function: ON/OFF
Analog to Digital rate: 7.5/15/30/60 times/Second.
Set zero point Value, when the scale shows zero, the screen will
show-–xxx.xxx
RS-232 Mode CONT(Stream send data)
ST1: Stable and send once
STC: Stable and send stream
PR1: Manual press PRINT key to send once
PR2: Manual press PRINT and M+ key to send once and accumulation...
AUTO: Stable send once and accumulation.
ASK: two way communication.
R: Read
T: Tare command
Baud rate: 600/1200/2400/4800/9600
Parity: 7E1/7O1/8N1
0, 0.0, 0.00, 0.000
(Decimal Setting)
Division 1, 2, 5, 10, 20, 50
Full Capacity xxx.xxx
Calibration
Internal count xxx.xxx
Release key lock OFF/ON
ON (Animal Mode)
OFF (Normal Mode)
Select unit(on) 。
Tj (Taiwan Kg) and Hj (Hongkong kg) can not be used at the same time.
Shut off Taiwan Kg when Hongkong kg is used.
Z: Zero Command
- 5 -