Do not start the burner if the combustion chamber contains oil or oil vapor.

Initial Start-up/Power-up

When powered-up for the first time, the control will display
a scrolling message "Does Burner Have A Solenoid Valve?".
G
H
Press
for Yes or
for No. This information is needed for
proper operation of the control. NOTE: The control will not
operate until this question is answered.
SOLENOID
Does Burner...
Press
=No
NOTE: This selection can be changed in the Settings Mode
(see below for how to change settings)

View or Change Control Setting

To enter the Settings Mode: Press the
simultaneously for 2 seconds. The display will show –
Settings Press
To Exit Hold
Carlin Combustion Technology, Inc.

Low Voltage Wiring

Press any button to activate display
Jumper
CAD
or
Cell
Thermostat
=Yes
G
E
and
buttons
4
N.O.
Vent
Dry
Switch
Contacts
To View Current Settings: Press the
through all Setting Modes (see table at the top of page 5 for
Setting Mode options). The second line of the screen will
display the current setting for each Setting Mode –
Valve Delay On
30 Seconds
E
Pressing the
button again will leave the setting as is and
move to the next option –
Trial for Ign
15 Seconds
To Change a Setting: Scroll to the desired Setting Mode
option using the
E
button (as described in table on page
H
5), then press the
or
button to scroll through the avail-
able Settings. When the desired setting is displayed on the
E
screen press the
/ ENTER button. The display will briefly
indicate that the new setting has been "Entered" and the new
setting will replace the previous setting on the second line of
the screen. Continue pressing the
rent setting for all options or
changes.
Trial for Ign
30 Seconds
To Exit the Setup Menu: Press the
seconds. NOTE: The control will automatically exit the Setup
menu after 30 seconds of inactivity or by a call for heat.
E
button to scroll
E
button to view the cur-
H
button to make any desired
F
/ ESCAPE button for 3
MN70200B 060217