AirStage AOUA36RLAVM Manuale di installazione rapida - Pagina 3
Sfoglia online o scarica il pdf Manuale di installazione rapida per Pompa di calore AirStage AOUA36RLAVM. AirStage AOUA36RLAVM 16. J-ii series
AOU36, 48, 60RLAVM Outdoor Unit(s)
208-230V/1 phase
50-130% Connected Capacity Indoor Unit(s)
208-230V/1 phase
Separation Tube Assemblies or Headers
Correctly sized line sets (both lines insulated separately)
Nitrogen & regulator capable of 600 PSIG
Vacuum pump and micron gauge
R-410a manifold gauges
Normal tools for installation
Product Weight (LBS)
AOUA36RLAVM
260
AOUA48RLAVM
262
AOUA60RLAVM
269
Refer to the Installation Manual for complete installation details.
1
This "Quick Installation Guide" is not
intended to replace the Installation Manual
shipped with each piece of equipment.
Don't take shortcuts and don't follow any "Rule of Thumb"
Conform to all Local, State & Federal
codes during installation.
Don't apply power to the equipment until
ready to start and test.
Adhere to all safety and installation warnings
within the Installation Manual for each unit.
J-II systems are CHARGED BY WEIGHING IN ADDITIONAL
REFRIGERANT ONLY. Do not charge by subcooling, superheat, by
pressures or any other alternative method.
Height
52 1/2"
Width
38 3/16"
Depth
14 9/16"
2
2
4