Drazice OKCE 160 -2/6 kW Manuale operativo e di installazione - Pagina 11

Sfoglia online o scarica il pdf Manuale operativo e di installazione per Scaldabagno Drazice OKCE 160 -2/6 kW. Drazice OKCE 160 -2/6 kW 19. Tank-type water heater for vertical mounting

Drazice OKCE 160 -2/6 kW Manuale operativo e di installazione

2.4 ELECTRICAL INSTALLATION

2.4.1 GENERAL INFORMATION FOR ELECTRICAL INSTALLATION

Execute the connection as indicated in the wiring diagram. Factory connection must not be changed!
(Figure 8). In the electric wiring cabinet remove the partition corresponding with the input wire diameter
of Ø8 or Ø10 (Figure 7). The degree of protection of electric parts of the heater is IP 44. Power input of electric
element is 3x2200 W. Use pre-installed brackets to hold the lead cable.
Figure 6
Ø10
Ø8
Figure 7
Ø8
Ø10
- 11 -