ANCEL AJ600 GDI Piezo Manuale di avvio rapido - Pagina 13
Sfoglia online o scarica il pdf Manuale di avvio rapido per Apparecchiature di prova ANCEL AJ600 GDI Piezo. ANCEL AJ600 GDI Piezo 14. Injector cleaner & tester
ANCEL
Add a small amount of test solution into the fuel tank, connect the fuel outlet hose of the device to the fuel return
port and power on the device. Select "Leakage test" item and press RUN button to run the device for about 2∼3
minutes. After the running has stopped, drain the test solution from fuel tank and dispose the drained liquid
according to relevant regulations.
3)
Clean up the site and tidy up the washing machine for later use.
Note:
1) When cleaning, care must be taken as the detergent is inflammable. Prepare at least one effective fire
extinguisher.
2) Be sure that all lines are well connected and there is no leakage before performing cleaning.
VI. Transporting and Storing
Transporting
6.1
1)
Before being packed, the liquid inside the fuel tank should be drained completely to avoid overflowing as
transporting.
2)
Move only by hand or lift with soft belt.
3)
No package no lifting tools or long-distance transportation.
4)
To prevent the unit from shocking and knocking, make sure it is on the base seat and in the packing case during
transportation. Firstly pack the unit with the matter similar with plastic strip and add the filling material (such as
foam or sponge, etc.) between the unit and packing case to avoid scratching the surface when the unit shakes.
5)
Make sure that the maximum incline angel does not exceed 45℃. Do not place the unit up-side-down.
Storing
6.2
1)
Store only in dry area and keep away from water before the unit is unpacked.
2)
Store the machine in well-ventilated area and do not expose it to direct sun shine or rain.
Installation Environment
6.3
1)
Keep a distance of no less than 200mm between the unit and any wall or other substance. The unit should be put in well-
ventilated area. Make sure the temperature is within -10℃+40℃.
2)
The unit has been well grounded for safety operation. Please confirm that the power socket is also well grounded
AJ600 GDI Piezo Injector Cleaner & Tester