ANCEL AJ600 GDI Piezo Manuale di avvio rapido - Pagina 5
Sfoglia online o scarica il pdf Manuale di avvio rapido per Apparecchiature di prova ANCEL AJ600 GDI Piezo. ANCEL AJ600 GDI Piezo 14. Injector cleaner & tester
ANCEL
testing processes can be controlled automatically and the parameters of the main status can be monitored in real
time.
Automatic fuel drain during a certain test can be realized via a routine, owing to the adoption of automatic fuel
drain control technology. Start or [Stop] fuel drainage via the [Drain] button on the control panel in running or
stop state..
Adopting humanization design can make the system pressure fast restored to the default values.
1.3 Working conditions & Specifications
Working conditions:
Temperature: -10~+40℃ Relative humidity: <85%
Intensity of outer magnetic field: <400A/m
No naked flame within 2m.
Specifications:
Main unit power supply: AC220V±10% 50Hz/60Hz or AC110V±10% 60Hz
Input power: 230W
Ultrasonic cleaner power: 100W
Resistance test accuracy: 0.1
Simulated RPM range:100~9900rpm, step:10rpm
Time range: 5~300s, step:5s
Pulse width: 0.1~25ms,step: 0.1ms
Fuel tank capacity: 2000 ml
Work pressure: 0-7bar
Ω
2
AJ600 GDI Piezo Injector Cleaner & Tester