5. Regulatory Agency

5.1 Safety Approvals
This series design shall meet the standards of the following domestic and foreign
agencies:
CE LVD
5.2 EMI/EMS Emission Approvals
This series design shall meet following EMI/EMS specifications:
FCC Compliance: FCC Rules and Regulations, Part 15, subpart B, Class A.
CE COMPLIANCE: EN55022 class A, EN55024, EN50130-4

6. Reliability

Mean Time Between Failures (MTBF):
MTBF shall be 50,000 hours minimum at 90% confidence level and 100% duty
cycle continuous operation at 25
Battery.
To avoid persistent image on OLED panel, do not leave any stationary images,
patterns or letterbox image on the screen for an extended period of time. This may result
in permanent burnt or ghost image on the screen. This type of damage is normal and is
not covered by manufacturer's limited warranty.
: EN 60950-1
o
C. The calculation shall not include OLED panel and