SPECIFICATIONS:
GAIN
NOMINAL LEVELS
PEAK LEVELS
balanced
NOISE 20kHz B.W.
HARMONIC DIST.
FREQUENCY RESP.
CROSSTALK
INPUT IMPEDANCE
OUTPUT IMPEDANCE
PHANTOM POWER
DIMENSIONS in. (cm)
CONNECTORS:
POWER:
Audio Technologies Inc. | 154 Cooper Road #902 | West Berlin, NJ 08091 | Voice 856-719-9900 | Fax 856-719-9903 | www.
DA103 40, 30,16dB maximum.
DMA103 80, 60, 40, 30dB maximum
DA103 +4dBu in, +4dBm out at –4dB preamp gain
DMA103 –50dBu in, +4dBm out at 40dB preamp gain
DA103 +22dBu in, +22dBm out to 600 ohm balanced
DMA103 -20dBu in, +22dBm out to 600 ohm
DA103 EIN -85dBu at unity gain
DMA103 EIN -124dBm at 54dB gain
.02% Max at Peak Levels, .01% max. at Nominal
Levels, 20Hz to 20 kHz
-.25dB, 20 to 20,000Hz
70dB minimum at 10kHz
Balanced, 20kohm bridging
Balanced, 40 ohms maximum Zs
DMA103 only, 20.2VDC regulated, PH48-1 48VDC
phantom power accessory available.
1.75"(4.45)H by 5.6"(14.2)W by 5.75"(14.6)D; Weight
1.25 Lb, (.57Kg) Net
DA103: Two-piece, screw clamp, Phoenix type.
DMA103: XLR, locking.
24VDC @ .1A nominal, 22Vmin. to 30Vmax, loop thru
cylindrical connectors, 2.0mmID, sleeve is positive.