ATI Technologies L1000 Manuale di funzionamento e manutenzione - Pagina 4
Sfoglia online o scarica il pdf Manuale di funzionamento e manutenzione per Amplificatore ATI Technologies L1000. ATI Technologies L1000 5. Dual line amplifiers
ADJUSTMENTS
The amplifier has sufficient gain and output capability to overdrive some console
inputs, particularly those providing preamps for high-level input channels. A -1
0dBm line input will provide +8dBm output from the amplifier with the gain pot to
approximately 2 o'clock. 12 o'clock is approximately 0dBm output and 10 o'clock
is -10dBm output (unity gain).
The common mode adjustment pots R1 6 and R35 are factory set to an 80dB null
at 60Hz If disturbed, they can be readjusted by applying a common mode 60Hz
input to HI & LO input together referenced to ground and renulling R16 for CH
1/L and R35 for CH 2/R. The null drops to 40dB at 20kHz due to slightly unequal;
roll offs in the input RF bypass capacitors.
MAINTENANCE NOTES
Power supply voltages are +/- 18VDC nominal, dropping to +/- 16VDC under full
output. If zeners are replaced, remove Al, A2, and A3 ICs and check output
voltage before plugging ICs back into the circuit. Remove power when inserting
or removing ICs.
IC output DC voltages (no signal conditions) should measure OVDC +/- .5VDC.
Significant deviation indicates IC or circuit problem. Measurable DC difference
between +/- amplifier inputs (other than due to meter loading) indicates IC failure.
MODIFICATIONS - 230 VAC OPERATIONS
Your L1000 is wired for 115 VAC 50/60 Hz operations unless otherwise
requested at the time of ordering. It can be modified for 230 VAC use by
removing the Power transformer primary jumpers W1 and W3 and inserting a
jumper in the W2 holes.
Audio Technologies Inc. | 154 Cooper Road #902 | West Berlin, NJ 08091 | Voice 856-719-9900 | Fax 856-719-9903 | www.