ANDELI MCT-520DPL Manuale d'uso - Pagina 3
Sfoglia online o scarica il pdf Manuale d'uso per Sistema di saldatura ANDELI MCT-520DPL. ANDELI MCT-520DPL 8. Multifuction welding&cutting machine
Anche per ANDELI MCT-520DPL: Manuale d'uso (20 pagine)
1 Wire Check Button
2 Welding model selection: MIG 2T/MIG 4T, Plasma CUT, HF TIG, Cold TIG, MMA
3 MIG Synergic/MIG Manual/TIG PULSE Selection: Press to select MIG Synergic mode (wire diameter) or MIG Manual mode or DC Pulse TIG
4 TIG Parameter Selection Button: Press to select different TIG parameters (move right)
5 Parameter Adjust Knob: Adjust to increase or decrease various parameters
6 TIG Parameter Selection Button: Press to select different TIG parameters (move left)
7 Function Selection Button: Press to select CO2 / mixed gas / gasless in MIG mode, or VRD in MMA mode, or 2T/4T trigger in TIG mode
8 Function Selection Button: Press to select Hot-start / Hot-start time / Arc-force in MMA mode, or Inductance in MIG mode, or 2T/4T trigger in CUT mode
9 Job Storage Button: Press to call the saved job (total 10 groups of jobs). Parameters of one job will be saved after 5 seconds without adjustment
10 Digital Display for Job Number
11 Digital Display for Current, Wire Feeding Speed, Hertz
12 Digital Display for Voltage, Pulse Width, Pulse Time
13 Gas Check Button
6.INSTALLATION INSTRUCTION
The machine is equipped with power voltage compensation device. When the power voltage fluctuates between±15% of rated voltage, it still can work normally.
When the machine is used with long cables, in order to prevent voltage form going down, bigger section cable Is suggested. If the cable is too long, it may have great affluence on
the arc-striking or other performance of cutting system, e.g. the HF arc-striking performance get weak or the system work abnormally. So cables of configured length are
suggested.
6.1 Make sure intake of the machine is not blocked or covered to avoid malfunction of cooling system.
6.2 Connect the protective gas source. The gas supply passage shall include a gas cylinder, an argon gas pressure reducing flowmeter and a gas pipe. The connecting portion of
the gas pipe shall be fastened with a hose clamp or other articles to prevent argon gas leakage and air ingress.
6.3 Ground the cables with section area no less than 6mm2 to the housing, the way is connecting screw in the back of the power source to ground device, or make sure ground
terminal of power socket is firmly connected. Both ways can be used for absolute safety.
6.4 Plug the quick plug of the loop cable into the quick socket of the welder panel with a polarity of "+" and follow The hour hand is tightened tightly, and the ground wire clamp
at the other end clamps the workpiece
6.5 When using the foot switch control, connect the two-core aviation and three-core aviation plugs of the foot switch to the three-core air socket of the local panel.
6.6 According to the input voltage level of the welding machine, connect the power line to the distribution box of the corresponding voltage level. Do not connect the wrong
voltage. Also ensure that the error of the power supply voltage is within the allowable range.
6.7 When using manual arc welding, install the electrode holder as shown. After the above work
is completed, the welder is finished. In the installation work, welding is available.
7.OPERATION INTRODUCTION
7.1 Use AC TIG welding function description: