ATI Technologies 39-0080 Manuale di servizio - Pagina 10

Sfoglia online o scarica il pdf Manuale di servizio per Strumenti di misura ATI Technologies 39-0080. ATI Technologies 39-0080 15. Milk meter

Innovation In and Out of Parlour

Milk Meter Fault Finding Scheme

ACR Faults

Symptom
ACR ram does not raise/lower cluster
No vacuum/vacuum always on at clawpiece
Premature ACR operation
Cluster removed at end of milking too
soon or too late
10 | Milk Meter Service Manual | v1.2
Possible Cause
PCB output fault
Solenoid valve fault
Wiring connection fault
Water in connection box
PCB output fault
Solenoid valve fault
Wiring connection fault
Shut-off valve always closed
Milk tube disconnected
Milk tube or milk meter blockage
ACR setting incorrect
See 'Meter Not Metering' section
ACR setting incorrect
Vacuum delay setting incorrect
Solution
Check bottom LED on control unit.
Change control unit lid
Check solenoid.
Check vacuum supply.
Check wiring in connection box.
Check wiring in solenoid box.
Check cable glands and lid seal.
Check internal connectors for water damage.
Change connectors.
Check top LED on control unit.
If light on vacuum should be on.
If light off vacuum should be off.
If faulty, change control lid.
Check solenoid.
Check vacuum supply.
Check wiring in connection box.
Check wiring in solenoid box.
Check shut-off valve
Reconnect milk tube
Clear blockage
Check ACR setting
Check ACR setting
Check vacuum delay setting