Preparing for installation
7.1
Handling aleo modules
7.1.1 Storing modules
■
Framed modules
Modules in packaging units:
NOTE
• Store the aleo modules upright in the packaging
units. Make sure that each module has sufficient
support.
• Do not stack the packaging units. This could damage
the modules.
Individual modules:
NOTE
• Store individual aleo modules in an upright position
on wedges with suitable padding. Use adequate pad
ding between the individual modules.
• Avoid stacking individual modules, as well as the
pallets they rest on.
7.1.2 Unpacking modules
■
Framed modules
NOTE
• Using an underlay, incline the pallet (e.g. with a
beam, height approx. 10 cm for 5° inclination), so
that the opening on the front of the box is elevated.
The modules then lean back in the box which makes
it easier to remove them.
• Use an underlay for inclining which supports the
whole side of the pallet (e.g. a beam). This keeps
the modules supported in the box along their entire
width.
• Remove the module from this side only. Remove the
module with the help of another person, if possible.
• Observe the unpacking instructions on the module
box.
7.1.3 Checking modules
NOTE
• Before installation, check each aleo module forme-
chanical defects. Pay particular attention to possible
damage to glass panels and insulated back sheets.
• In addition, check the insulation on the cables,
connectors and junction boxes.
• If you discover any defects, report them to the
supplier or transport company immediately.
Page 6/19
7.1.4 Transporting modules to the installation site
■
Framed modules
NOTE
• Always carry the aleo module with one other per
son. Take hold of the module on its long sides.
• When transporting individual modules, make sure
that you do not put any strain or pressure on the
junction box and cables.
7.2
Safety precautions
DANGER
When installing on roofs or other elevated sites,
objects may fall down.
Severe or fatal injuries are possible!
• Block off the danger zone for people and animals
before beginning installation work. If possible,
remove all objects from the danger zone.
_______________________________________________
DANGER
Electric arcs form when electrical connections
are made or disconnected incorrectly.
Severe or fatal injuries from electric shock or
severe injury from burns!
• Disconnect the photovoltaic generator before you
carry out any work on the electrical components of
the photovoltaic generator.
_______________________________________________
DANGER
High DC voltages, even when the photovoltaic
generator is disconnected, if the generator is
earthed.
Severe or fatal injuries from electric shock!
• If the circuit of your photovoltaic generator is
earthed, remove the earth before carrying out
electrical work on the generator.
_______________________________________________
WARNING
Exposed live parts on damaged modules.
Danger of electric shock!
• Only use components which are in perfect condition
for use in photovoltaic systems. Do not install solar
modules with visible damage to the glass panels,
the insulating back sheet or on the insulation of
electrical connections.