Aleo X81 Manuale di installazione - Pagina 14

Sfoglia online o scarica il pdf Manuale di installazione per Unità di controllo Aleo X81. Aleo X81 20.

Aleo X81 Manuale di installazione
10.7

Mounting drawings for modules with standard frame

10.7.1 Module X63, X83
0 mm
300 mm
220 mm
120 mm
Fig. 9
Mounting X63/X83 with clamps
Clamping
long side
Clamping
short side
Table mounting areas clamping for X63, X83
Lay-in system
long side
Lay-in system
short side
Table lay-in system for X63, X83
aleo solar GmbH | Marius-Eriksen-Straße 1 | 17291 Prenzlau | Germany |
458 mm
Clamping area
0 mm – 458 mm
120 mm – 458 mm
220 mm – 458 mm
220 mm – 300 mm
0 mm – 200 mm
Permissible pressure
Load level
(test load)
Load level II
3900 Pa
Load level I
2400 Pa
Modules can be mounted horizontally and
vertically.
Please note the information on snow load
in section 10.6.4.
Permissible pressure
Load level
(test load)
Load level I
2400 Pa
Load level II
3900 Pa
Load level III
5400 Pa
Load level IV
8000 Pa
Load level I
2400 Pa
Permissible suction
(test load)
2400 Pa
2400 Pa
Installation manual Ver. 4.8, 05/2021, en
Permissible suction
(test load)
2400 Pa
2400 Pa
2400 Pa
5400 Pa
2400 Pa
Page 14 of 20