Anderson 52G3600 Manuale operativo - Pagina 3
Sfoglia online o scarica il pdf Manuale operativo per Bruciatore Anderson 52G3600. Anderson 52G3600 8.
This manual has been written for those who are already familiar with all aspects of nozzle mix
burner and its add-on components. Main contents of the manual including safety rules, burner
installation, commissioning, operation parameters, maintenance and troubleshooting, spare
parts, etc.
1. Disclaimer Notice
Anderson Thermal Solutions (Suzhou) Co., Ltd. reserves the right to change the construction
and/or configuation of our product at any time without informing customers.
If the product or its individual modules are used for purposes other than the designated purpose,
their effectiveness and suitability must be confirmed.
Anderson warrants that the product itself will not infringe any patents. Every effort has been
made to make this manual as accurate and complete as possible. If you find errors or omissions,
please contact us so we can correct
2. Liability and Warranty
Due to negligence, breach of warranty or other reasons, Anderson's liability for its products is
limited to the provision of such replacement parts and will not be liable for any other injury, loss
or expense, whether direct or indirect, including but not limited to Loss of or damage to the use
of materials that sell, install, use, fail to use or repair or replace Anderson related products.
The warranty is void if: any operation explicitly prohibited in this manual, any adjustment or
assembly process not recommended or authorized.
3. Safety instructions
Only those who were trained and qualified person can follow the manual to operate or adjust
the combustion system. The fire was prohibited within a radius of 5 meters of the combustion
system. Flame, non–covered light sources or heat sources shall not be brought to the combustion
area unless it is related to the process. Welding in combustion control area shall be approved to
ensure the safety in the area and also preventive measures should be taken into consideration.
Before starting, the operator must confirm whether the burner and gas pipeline are in normal
working condition, and there is no flammable substance around the burner. The burner must be
operated with fuel and oxygen or air. The ignition and operation of the burner must be performed
at the specified position. The burner has been correctly and safely installed before ignition. The
ignition of the burner needs to be performed after the combustion chamber is purged. If it is
ignited at a low temperature, it needs to be replaced with 5 times the volume of the combustion
chamber to avoid explosion.
Anderson Thermal Soluions(Suzhou)Co., Ltd
Anderson Thermal Solutions – FFO52 Burner Operation Manual
them.
2