Sfoglia online o scarica il pdf Manuale per Sensori di sicurezza Aleph XC-1XTEU. Aleph XC-1XTEU 3. Xc-1xt series. outdoor dual technology intrusion detector 40ft l x 56 w (12m x 17m)

DetectionPattern Ilustration(Standard Lens)
0
1.5
3.0 4.5
6.0
28
25
20
15
10
5
0
5
10
15
20
25
28
0
5
10
15
20
Troubleshooting:
Trouble
Cause
Unit does not power up.
No or low input power.
Input power polarity reversed.
Alarm LED does not light up.
SW-4 is set to ON/ Disabled
Detedtion Sensitivity setting incorrect.
Pulse Count setting incorrect for area.
Alarm LED/ Relay Triggers W/O
Incorrect Sensor mounting height.
movement in the detection area
Unsecured environment animals/rodents
in protected area.
Machinery operating in sensor view
Direct sunlight/headlight in sensor view.
Severe vibration at mounting wall.
LED indicates alarm, no alarm output
Incorrect wiring at alarm output terminals.
Open circuit in wiring between detector &
control panel.
Lightning damage to detector and/or control
panel.
MODEL : XC-1XT
FCC ID: DNHXC-002-00
FCC Information:
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
- Consult the dealer or an experienced radio / TV technician for help.
The user should not modify or change this equipment without written approval from ALEPH.
Modification could void authority to use this equipment.
Power Requirements
9.5-16 VDC, 12VDC Nominal
Current Draw
35 mA Max.
Warm Up Period
<50 Seconds
Alarm Period
2.4 Seconds
LED Indicators
Red = Alarm
Amber = Microwave
Green = PIR
Weight
6.2 oz. (176 g)
MW Detector Type
10.525GHz (US and EU)
10.687GHz (UK)
PIR Sensitivity
Four Adjustable Settings
60%, 80%, 100% and 120%
MW Range adjustment
Adjustable via a Potentiometer
Mounting Height
6.6 ft (2.0m) to 8.2ft (2.5m)
In a continuing effort to improve product performance, specifications
and design characteristics may be changed without prior notice.
P/N 9-900-009-00 Rev. A
7.5
9.0 10.5 12.0
8.5
7.5
6.0
4.5
3.0
1.5
0
1.5
3.0
4.5
6.0
7.5
8.5
25
30
40
35
Remedy
Apply proper input voltage.
Correct wiring polarity.
Set SW-4 to "OFF".
Set SW-1 &2 and/or MW range
adjustment to match desired area.
Set SW-3 to correct PC.
Increase/Decrease mounting height.
Block animal/rodent access.
Remove the hazard / Re-aim sensor so
it is not viewing hazard/machinery.
Switch detection mode to "Dual", add
curtain/shade to block light sources.
Buffer mounting with plywood. Relocate XC-1XT
mounting position.
Correct wiring fault.
Replace/ Repair wiring.
Replace damaged equipment.
Specifications
Alarm Output
Tamper Output
Operating Temperature -4°F to +122°F (-20°C to +50°C)
Humidity Limits
Dimensions (H x W x D) 6.3in.(L) X 2.76in.(W) X 1.73in.(D)
PIR Detector Type
Range Stand. Lens
Range Optional Lens
(Curtain)
Pulse Count
IP Rating
U.S. & International Patents Pending
.75
1.5
3.0
4.5
8.5
0
Aleph hereby declares that the XC-1XTEU and XC-1XTUK Intrusion Detector is in compliance with the
essential requirements and other relevant provisions of Directive 1999/5/EC. The declaration of conformity may
be consulted at http://www.alepheurope.com/
MODEL : XC-1XTEU
{European info here}
Testing and Maintenance:
- INSPECTION: An inspection of this unit should be made periodically, consisting of, but not
limited to all mounting, wiring and the condition of the interior components.
- CLEANING: Clean the external plastic parts of this unit with a soft, damp cloth.
- TESTING: This unit should be tested routinely for proper operation. At a minimum,
operation should be fully checked yearly.
- NOTES: This unit is designed to be incorporated into an overall alarm system. As it is part
of the system ALEPH cannot assume responsibility for theft or damage if the system fails to
operate.
Nippon Aleph Corporation
Two Form C
(NC/NO)outputs
-Security Products Headquarters-
30 VDC/350mA Max.
1-28-52, Komaoka, Tsurimi-ku,
NC/ 30VDC/500mA
Yokohama-shi, Kanagawa-ken
JAPAN, 230-0071
Tel: +81 045-575-4290 / Fax: +81 045-580-1676
95% Max. Non-condensing
WEB: http://www.nippon-aleph.co.jp
(160mm x 70mm x 43.9mm)
Aleph America Corporation
4700 Aircenter Cir, Reno, NV, 89502
Dual Element
40ft L x 56ft W
USA
80ft L x 8ft W
Tel: 775 827 8000 / Fax: 775 827 8044
2 or 4 Step Catch
WEB: http://www.aleph-usa.com
Aleph Europe Ltd.
IP54
1 Newton Close, Park Farm Industrial Estate
Wellingborough, Northamptonshire, NN8 6UW
England
Tel: 044 193 367 9600 / Fax: 044 193 340 1165
WEB: http://www.alepheurope.com
6.0
7.5
9.0
10.5
12.0
Rear Cover (Interior View, PCB removed)
= Six Mounting Points available.
When installing this unit in a corner mount
application, install screws into one side of the
case. Installing screws into both sides of the
case when walls are uneven causes the plastic
case to become distorted thus water can be
allowed entry into the unit.
Exterior Wiring Channel
After wiring, install the foam wiring access bug
guard to prevent ingress of dust and insects.
MODEL : XC-1XTUK