A 20 pound (9 kg) cylinder should
SAFETY
INSTRUCTIONS
be used with this appliance.
3. Remove the protective cap from the LP cylinder
valve, if installed and connect the hose and gas
regulator assembly to the LP cylinder.
Be careful not to cross thread the
NOTICE
connector onto the valve. Hand
tighten only. Do not use tools to tighten this
connection.
4. Make sure the hose is not kinked and is routed
away from any sharp edges or hot surface. The
LP cylinder should be placed at least 18 inches
away from the appliance.
The supply hose can be a trip
WARNING
hazard. Tripping over the gas
supply hose can cause spillage of hot oil or food,
resulting in serious burns. Place the LP cylinder
away from human or pet traffic. Do not walk
between the appliance and the LP cylinder.
5. Perform the Soapy Water Test described in the
following section to check for leaks.
5.3 Soapy Water Test
SAFETY INSTRUCTIONS
• The soapy water test must be performed outdoors
in a well-ventilated area.
• Do not perform the test around open flames,
sparks, lit matches, lighters, or cigarettes.
• Never use an open flame to test for gas leaks.
The "soapy water test" must be performed each time:
the LP cylinder is reconnected, or
đ
any time the appliance has been moved, or
đ
at least once per year or if the appliance has not been
đ
used for more than 60 days.
Model M56913
January 2018
1. Remove any cookware or oil vats from the
appliance.
2.
The shut-off valves and the LP cylinder
valve should be in the OFF or closed
OFF
position.
3. Prepare a soapy water solution by combining one
part dish washing liquid with three parts water.
4.
Open the LP cylinder valve.
ON
(with the shut-off valves in the closed
position).
OFF
5. Apply the soapy water solution to ALL
connections between the LP cylinder and the
shutoff valve on the gas control valve.
Close the LP cylinder valve
WARNING
immediately if bubbles appear.
Retighten the loose connection and repeat the test.
6. If leaks are identified between the LP cylinder
and the unit's shutoff valve, immediately turn
OFF the LP cylinder valve.
7. If connections are leak-free, continue to Step 10.
8. All connections with evidence of leaking should
be tightened, then repeat Steps 4 and 5.
9. If after tightening any loose connections bubbles
continue to appear, close the LP cylinder valve,
disconnect the LP cylinder, and do not use the
appliance. Contact the local retailer where the
appliance was purchased.
10. Continue with the Lighting Instructions or if the
appliance will not be used immediately, close all
gas valves and disconnect the LP cylinder.
5.4 Lighting Instructions
Note: To prevent leaving the appliance unattended,
have the food prepared, safely stored, and outdoors
before lighting the appliance.
1.
Make sure the shut-off valve is in the
closed position before lighting.
OFF
WARNING
hands, hair, and face away from the burner. Do not lean
over the appliance when lighting the burner or cooking.
10
Do not place any part of the
body above the appliance
when lighting. Keep your
Carolina Cooker