ATIM ACW-PIR360-I Manuale d'uso - Pagina 9

Sfoglia online o scarica il pdf Manuale d'uso per Modem ATIM ACW-PIR360-I. ATIM ACW-PIR360-I 19.

b. Alarm mode
In this mode, the product transmits a frame as soon as it detects a presence. This mode is relevant for detecting
intrusions and being warned instantly.
A periodic frame can also be configured, to get windows of downlinks more often.
CAUTION: The methods for detecting presence may change from one product to another. Remember to refer to the
corresponding Optex documentation to learn more about the detection method.
Product
ACW-PIR360-I
ACW-PIR90-I
ACW-PIR180-O
ACW-PIR90-O
ACW-ILB30
ACW-ILB100
NOTE: ISM band regulations impose a limit on the daily transmission time (duty-cycle). This usually means limiting
the broadcast to one frame every 10 minutes.
It is possible to reduce this period if during part of the day the product no longer emits.
For example, if you want to have an active alarm from 6 p.m. to 6 a.m. (12 hours of operation) then you can reduce
the minimum transmission period to 5 minutes.
Conclusion, although the minimum time between 2 detections is less than 10 minutes, by default, the sensor does
not transmit within 10 minutes after the last frame sent.
Minimum time between 2 detections
2 minutes
2 minutes
5s minimum / 120s recommanded
5s minimum / 120s recommanded
5s minimum / 120s recommanded
5s minimum / 120s recommanded
ATIM_ACW-PIR_UG_EN_V1.4