System Configuration Window

The "System Configuration" window provides access to setting global configurations and status view of major
parameters.

User Inputs

Power Management Mode (PM)
» None: Power Management will not be performed by the firmware. User needs to power up the ports manually.
» Static /w Priority: Power is budgeted statically based on selected violation type.
› If violation type is "Class Based", then maximum permissible power for that class is budgeted.
› If violation type is "User Defined", then the configured user-defined limit is budgeted.
› If violation type is "None", then budgeted power is based on port mode.
› For Normal Mode the power budgeted is 16.2W
› For High Power Mode the power budgeted is based on ILIM/ICUT selected value.
· For ILIM/ICUT – 504/465 mA, the power budgeted is 22.5W
· For ILIM/ICUT – 563/545 mA, the power budgeted is 26.5W
· For ILIM/ICUT – 850/625 mA, the power budgeted is 31.6W
· For ILIM/ICUT – 850/725 mA, the power budgeted is 37.0W
» Static /wo Priority: Same as above except that port priority of the port is ignored.
» Static /wo Priority: Power is budgeted statically based on selected violation type.
› If violation type is "Class Based", then maximum permissible power for that class is budgeted.
› If violation type is "User Defined", then the configured user-defined limit is budgeted.
› If violation type is "None", then budgeted power is based on port mode.
› For Normal Mode the power budgeted is 16.2W
Tech SupporT: 1.888.678.9427
Figure 7: System Configuration Window
Power Management can be used in the following modes: