Comnet CNMC SFP Series Manuale di installazione e funzionamento - Pagina 4
Sfoglia online o scarica il pdf Manuale di installazione e funzionamento per Convertitore multimediale Comnet CNMC SFP Series. Comnet CNMC SFP Series 5. 10/100/1000mbps ethernet to vdsl2 media converters
INSTALLATION AND OPERATION MANUAL
FIGURE 5 – LED INDICATORS
SFP-VDSL LINK
GREEN
Link
YELLOW
–
OFF
No Link
FIGURE 6 – POSSIBLE ETHERNET CONFIGURATION
Ethernet IEEE 802.3 Network Element determined by user.
CAT5e/6 with
RJ45 Connections
100m (328ft)
Ethernet IEEE 802.3
Network Element
INSTALLATION & OPERATION
SFP-VDSL is a book-end solution that allows for connectivity over long 2 wire twisted cable. To install and connect SFP-VDSL interface:
•
Connect SFP-VDSL devices using a twisted 2-wire cable (use pins 4 & 5). Always connect SFP-VDSLA to a SFP-VDSLB.
•
Link synchronization may take up to one minute.
SFP-VDSLAB Specifications
Interface
Type
1000BaseFX
Connector
SFP / MSA Compliant
Connectors
RJ-45
Data Rate
Up to 150 Mbps
Power
Operating Voltage
12 V
Power Consumption
3 W Max
Mechanical
LED Indicators
Power / Link Status on side of SFP module
Dimensions (H x W x L)
0.54 × 0.67 × 3.12 in (13.7 × 17.0 × 79.2 mm)
Weight
1.13 oz / 32.0 g
Environmental
Operating Temp
-40°C to +75°C
Storage Temp
-40°C to +85°C
Relative Humidity
0 to 90%, non-condensing
TECH SUPPORT: 1.888.678.9427
COPPER
POWER
Solid – No Activity
Unit powered up
Blinking – Activity
Highest Data Rate
–
No Link
Unit powered down
Connect
SFP-VDSL devices
using a twisted
2-wire cable.
CNMCSFP/M
FIGURE 7 - BANDWIDTH VS DISTANCE
160
140
120
100
80
60
40
20
RJ45 Connections
CNMCSFP/M
0
0
500
1000
1500
CNMC[2]SFP/[M]V SERIES
CAT5e/6 with
100m (328ft)
Ethernet IEEE 802.3
Network Element
2000
2500
3000
INS_CNMCSFP/V 06/06/12 PAGE 4