Electrolux EGG 685 Manuale di istruzioni - Pagina 13

Sfoglia online o scarica il pdf Manuale di istruzioni per Piano cottura Electrolux EGG 685. Electrolux EGG 685 17. Gas hob egg685
Anche per Electrolux EGG 685: Libretto di istruzioni (16 pagine), Libro di istruzioni (16 pagine)

Electrolux EGG 685 Manuale di istruzioni

Wiring Diagram

N
1
L

Fault Finding

Preliminary Electrical Systems
Check
1
220
240
2
3
0
4
2
START
Isolate appliance
and carry out:
A: Earth Continuity
check.
NO
YES
Carry out:
C: Polarity check.
Has inlet fuse blown?
NO
YES
Inlet wiring
faulty.
Rectify any
fault.
Isolate appliance and
carry out:
B: Insulation check.
Rectify any fault
including replacing
fuses as necessary.
A. IGNITOR SWITCH
B. IGNITOR UNIT
PLUG (with cover
removed)
( )
Carry out:
D: Resistance to
Earth check.
A. EARTH CONTINUITY CHECK - Appliance must be
electrically disconnected - meter set on W (Ohms) x
1 scale and adjust zero if necessary.
a) Test leads from any appliance earth point to earth
pin on plug. Resistance should be less than 0.1
ý (Ohm), check all earth wires for continuity and
all contacts are clean and tight.
B. INSULATION CHECK - Appliance electrically
disconnected, all switches ON.
a) meter set on W(Ohms) x 1 scale.
Test leads from L to N in appliance terminal block.
If meter reads «0» then there is a short circuit.
b) meter set on W (Ohm) x 100 scale.
Repeat test with leads from L to E. If meter reads
less than ¥ (infinity) there is a fault.
NOTE - Should it be found that the fuse has failed
but no fault is indicated - a detailed continuity check
(i.e. by disconnecting and checking each
component) is required to trace the faulty component.
It is possible that a fault could occur as a result of
local burning/arcing but no fault could be found under
test. However a detailed visual inspection should
reveal evidence of burning around the fault.
SOCKET
(face view)
( )
E
N
L
Electricity supply
should now be
satisfactory.
13