Wall Outlet Location
(12.7 cm)
Recommended
area for 120V
grounded
outlet on rear
wall.
Figure 4
or u_4tT
Provide
an Adequate
Gas Supply
This cooktop is designed to operate on natural gas at 4"
(10.2 cm) of manifold pressure only.
A pressure regulator is connected in series with the
manifold on the cooktop and must remain in series with
the supply line.
For proper operation,
the maximum inlet pressure to
the regulator must be no more than 14" (35.6 cm) of
water column (W.C.) pressure.
For checking the regulator, the inlet pressure must be at
least 1 "(2.5 cm) (or 2.5 kPa) greater than the regulator
manifold pressure setting. The regulator is set for 4"
(10.2 cm) of manifold pressure, the inlet pressure must
be at least 5" (12.7 cm).
The gas supply line to the range should be 1/2" (1.3 cm)
or 3/4" (1.9 cm) pipe.
LP/Propane
Gas Conversion
This appliance can be used with Natural gas or LPi
Propane gas. It is shipped from the factory for use with
natural gas.
A kit for converting to LP gas is supplied with your
cooktop. The kit is marked "FOR LPiPROPANE GAS
CONVERSION ".
The conversion must be performed by a qualified service
technician in accordance with the kit instructions and all
local codes and requirements. Failure to follow
instructions could result in serious injury or property
damage. The qualified agency performing this work
assumes responsibility for the conversion.
Failure to make the appropriate
conversion can result in personal injury and property
damage.
Important:
Remove all packing material and
literature from cooktop before connecting gas and
electrical supply to cooktop.
Install
Pressure
Regulator
Install the pressure regulator with the arrow on the
regulator pointing up toward the unit in a position where
you can reach the access cap.
Do not make the connection too tight.
The regulator is die cast. Overtightenh_g may crack the
regulator resulting in a gas leak and possible fire or
explosion.
_._ FLOW
V_ve
ur_i_
u_i_
_xbe
_g_r
All connections must be wrench-tightened
Figure 5
Assemble the flexible connector from the gas supply pipe
to the pressure regulator in the following order:
1. manual shutoff valve
2. 1/2" (1.3 cm) nipple
3. 1/2" (1.3 cm) flare union adapter
4. flexible connector
5. 1/2" (1.3 cm) flare union adapter
6. 1/2" (1.3 cm) nipple
7. pressure regulator
Use pipe-joint compound made for use with Natural and
LPiPropane gas to seal all gas connections.
If flexible
connectors are used, be certain connectors are not
kinked.