Technical information

DIMENSIONS
ELECTRICAL SUPPLY
SUITABLE FOR -
INSTALLATION ABOVE:
THIS APPLIANCE MUST BE EARTHED

Electrical Requirements

Any permanent electrical installation must
comply with the latest I.E.E. Regulations and
local Electricity Board regulations. For your own
safety this should be undertaken by a qualified
electrician e.g. your local Electricity Board, or a
contractor who is on the roll of the National
Inspection Council for Electrical Installation
Contracting (NICEIC).

Electrical Connection

Before connecting to the mains supply ensure
that the mains voltage corresponds to the
voltage on the rating plate inside the cooker

INSTALLATION INSTRUCTIONS

HEIGHT OF CANOPY:
HEIGHT OF CHIMNEY:(UPPER SECTION)
WIDTH OF CANOPY: EFC 635
DEPTH OF CANOPY:
VOLTAGE:
POWER CONSUMPTION:
FAN MOTOR:
LAMPS:
ELECTRIC HOB:
GAS HOB:
SLOT-IN ELECTRIC COOKER:
SLOT-IN GAS COOKER:
Note: CE Marking certifies that this appliance complies with the
requirements laid down in EEC directive 89:336 (Electromagnetic
compatibility) and subsequent modifications and Low Votage directive
72/23/E.
(LOWER SECTION)
EFC 935
(~50Hz)
(2 x40W)
This appliance is fitted with a 3 core mains cable
and must be permanently connected to the
electricity supply via a double-pole switch having
3mm minimum contact gap on each pole. A
Switched Fuse Connection Unit to BS.1363 Part
4, fitted with a 3 Amp fuse, is a recommended
mains supply connection accessory to ensure
compliance with the Safety Requirements
applicable to fixed wiring instructions.
This appliance conforms to BS.800:1988 and
EEC Directive No. 78 308 regarding suppression
of radio and television interference.
10
270mm
215mm
530mm
598mm
898mm
490mm
220-240V
225W
145W
80W
7KW (MAX)
10KW (MAX)
12.4KW (MAX)
13.5KW (MAX)