Daikin VRV-WII Series Manuale dei dati tecnici - Pagina 9

Sfoglia online o scarica il pdf Manuale dei dati tecnici per Condizionatore d'aria Daikin VRV-WII Series. Daikin VRV-WII Series 20. Concealed ceiling unit
Anche per Daikin VRV-WII Series: Manuale dei dati tecnici (20 pagine), Manuale dei dati tecnici (18 pagine)

Daikin VRV-WII Series Manuale dei dati tecnici
5
Capacity tables

5 - 2 Heating capacity tables

FXMQ-P
Nominal
Unit size
capacity
40
50
63
80
138
• Indoor Units • CONCEALED CEILING UNIT • FXMQ-PVE
Outdoor air temp.
°CDB
°CWB
5.0
-19.8
-20.0
-18.8
-19.0
-16.7
-17.0
-14.7
-15.0
-12.6
-13.0
-10.5
-11.0
-9.5
-10.0
-8.5
-9.1
-7.0
-7.6
-5.0
-5.6
-3.0
-3.7
0.0
-0.7
3.0
2.2
5.0
4.1
7.0
6.0
9.0
7.9
11.0
9.8
13.0
11.8
15.0
13.7
6.3
-19.8
-20.0
-18.8
-19.0
-16.7
-17.0
-14.7
-15.0
-12.6
-13.0
-10.5
-11.0
-9.5
-10.0
-8.5
-9.1
-7.0
-7.6
-5.0
-5.6
-3.0
-3.7
0.0
-0.7
3.0
2.2
5.0
4.1
7.0
6.0
9.0
7.9
11.0
9.8
13.0
11.8
15.0
13.7
8.0
-19.8
-20.0
-18.8
-19.0
-16.7
-17.0
-14.7
-15.0
-12.6
-13.0
-10.5
-11.0
-9.5
-10.0
-8.5
-9.1
-7.0
-7.6
-5.0
-5.6
-3.0
-3.7
0.0
-0.7
3.0
2.2
5.0
4.1
7.0
6.0
9.0
7.9
11.0
9.8
13.0
11.8
15.0
13.7
10.0
-19.8
-20.0
-18.8
-19.0
-16.7
-17.0
-14.7
-15.0
-12.6
-13.0
-10.5
-11.0
-9.5
-10.0
-8.5
-9.1
-7.0
-7.6
-5.0
-5.6
-3.0
-3.7
0.0
-0.7
3.0
2.2
5.0
4.1
7.0
6.0
9.0
7.9
11.0
9.8
13.0
11.8
15.0
13.7
®
• VRV
Systems • Indoor Units
Indoor air temperature
16.0
18.0
20.0
KW
KW
KW
3.0
2.9
2.9
3.0
3.0
3.0
3.2
3.2
3.2
3.4
3.4
3.4
3.6
3.6
3.6
3.7
3.7
3.7
3.8
3.8
3.8
3.9
3.9
3.9
4.0
4.0
4.0
4.2
4.2
4.2
4.4
4.4
4.4
4.7
4.6
4.6
4.9
4.9
4.9
5.1
5.1
5.0
5.2
5.2
5.0
5.4
5.3
5.0
5.6
5.3
5.0
5.6
5.3
5.0
5.6
5.3
5.0
3.7
3.7
3.7
3.8
3.8
3.8
4.1
4.0
4.0
4.3
4.3
4.3
4.5
4.5
4.5
4.7
4.7
4.7
4.8
4.8
4.8
4.9
4.9
4.9
5.1
5.1
5.1
5.3
5.3
5.3
5.5
5.5
5.5
5.9
5.9
5.8
6.2
6.2
6.2
6.4
6.4
6.3
6.6
6.6
6.3
6.8
6.7
6.3
7.0
6.7
6.3
7.1
6.7
6.3
7.1
6.7
6.3
4.7
4.7
4.7
4.9
4.9
4.8
5.1
5.1
5.1
5.4
5.4
5.4
5.7
5.7
5.7
6.0
6.0
6.0
6.1
6.1
6.1
6.3
6.3
6.2
6.5
6.5
6.4
6.8
6.7
6.7
7.0
7.0
7.0
7.5
7.4
7.4
7.9
7.8
7.8
8.1
8.1
8.0
8.4
8.4
8.0
8.7
8.5
8.0
8.9
8.5
8.0
9.0
8.5
8.0
9.0
8.5
8.0
5.9
5.9
5.9
6.1
6.1
6.0
6.4
6.4
6.4
6.8
6.8
6.8
7.1
7.1
7.1
7.5
7.5
7.5
7.7
7.7
7.6
7.8
7.8
7.8
8.1
8.1
8.1
8.4
8.4
8.4
8.8
8.8
8.7
9.3
9.3
9.3
9.8
9.8
9.8
10.2
10.1
10.0
10.5
10.5
10.0
10.8
10.6
10.0
11.2
10.6
10.0
11.3
10.6
10.0
11.3
10.6
10.0
TC: Total capacity;kW – SHC: Sensible capacity;kW
21.0
22.0
KW
KW
2.9
2.9
3.0
3.0
3.2
3.2
3.4
3.4
3.5
3.5
3.7
3.7
3.8
3.8
3.9
3.9
4.0
4.0
4.2
4.2
4.4
4.4
4.6
4.6
4.8
4.7
4.8
4.7
4.8
4.7
4.8
4.7
4.8
4.7
4.8
4.7
4.8
4.7
3.7
3.7
3.8
3.8
4.0
4.0
4.2
4.2
4.5
4.5
4.7
4.7
4.8
4.8
4.9
4.9
5.1
5.1
5.3
5.3
5.5
5.5
5.8
5.8
6.1
5.9
6.1
5.9
6.1
5.9
6.1
5.9
6.1
5.9
6.1
5.9
6.1
5.9
4.7
4.7
4.8
4.8
5.1
5.1
5.4
5.4
5.7
5.7
6.0
6.0
6.1
6.1
6.2
6.2
6.4
6.4
6.7
6.7
7.0
7.0
7.4
7.4
7.7
7.5
7.7
7.5
7.7
7.5
7.7
7.5
7.7
7.5
7.7
7.5
7.7
7.5
5.9
5.9
6.0
6.0
6.4
6.4
6.7
6.7
7.1
7.1
7.5
7.4
7.6
7.6
7.8
7.8
8.1
8.0
8.4
8.4
8.7
8.7
9.3
9.3
9.7
9.4
9.7
9.4
9.7
9.4
9.7
9.4
9.7
9.4
9.7
9.4
9.7
9.4
24.0
KW
2.9
3.0
3.2
3.4
3.5
3.7
3.8
3.9
4.0
4.2
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
3.7
3.8
4.0
4.2
4.5
4.7
4.8
4.9
5.1
5.3
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
4.7
4.8
5.1
5.4
5.7
5.9
6.1
6.2
6.4
6.7
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
5.8
6.0
6.4
6.7
7.1
7.4
7.6
7.8
8.0
8.4
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
8.7
CA08A056