5
Capacity tables
5 - 1 Cooling capacity tables
FXMQ-P
Outdoor
Unit
Nominal
air temp.
size
capacity
°CDB
TC
100
11.2
10.0
7.6
12.0
7.6
14.0
7.6
16.0
7.6
18.0
7.6
20.0
7.6
21.0
7.6
23.0
7.6
25.0
7.6
27.0
7.6
29.0
7.6
31.0
7.6
33.0
7.6
35.0
7.6
37.0
7.6
39.0
7.6
125
14.0
10.0
9.4
12.0
9.4
14.0
9.4
16.0
9.4
18.0
9.4
20.0
9.4
21.0
9.4
23.0
9.4
25.0
9.4
27.0
9.4
29.0
9.4
31.0
9.4
33.0
9.4
35.0
9.4
37.0
9.4
39.0
9.4
• Indoor Units • CONCEALED CEILING UNIT • FXMQ-PVE
14.0WB
16.0WB
20.0DB
23.0DB
SHC
TC
SHC
TC
6.4
9.0
7.3
10.5
6.4
9.0
7.3
10.5
6.4
9.0
7.3
10.5
6.4
9.0
7.3
10.5
6.4
9.0
7.3
10.5
6.4
9.0
7.3
10.5
6.4
9.0
7.3
10.5
6.4
9.0
7.3
10.5
6.4
9.0
7.3
10.5
6.4
9.0
7.3
10.5
6.4
9.0
7.3
10.5
6.4
9.0
7.3
10.5
6.4
9.0
7.3
10.5
6.4
9.0
7.3
10.5
6.4
9.0
7.3
10.5
6.4
9.0
7.3
10.5
8.0
11.3
9.2
13.1
8.0
11.3
9.2
13.1
8.0
11.3
9.2
13.1
8.0
11.3
9.2
13.1
8.0
11.3
9.2
13.1
8.0
11.3
9.2
13.1
8.0
11.3
9.2
13.1
8.0
11.3
9.2
13.1
8.0
11.3
9.2
13.1
8.0
11.3
9.2
13.1
8.0
11.3
9.2
13.1
8.0
11.3
9.2
13.1
8.0
11.3
9.2
13.1
8.0
11.3
9.2
13.1
8.0
11.3
9.2
13.1
8.0
11.3
9.2
13.1
®
• VRV
Systems • Indoor Units
Indoor air temperature
18.0WB
19.0WB
26.0DB
27.0DB
SHC
TC
SHC
TC
8.3
11.2
8.5
11.9
8.3
11.2
8.5
11.9
8.3
11.2
8.5
11.9
8.3
11.2
8.5
11.9
8.3
11.2
8.5
11.9
8.3
11.2
8.5
11.9
8.3
11.2
8.5
11.9
8.3
11.2
8.5
11.9
8.3
11.2
8.5
11.9
8.3
11.2
8.5
11.9
8.3
11.2
8.5
11.9
8.3
11.2
8.5
11.7
8.3
11.2
8.5
11.5
8.3
11.2
8.5
11.3
8.3
11.0
8.4
11.2
8.3
10.8
8.3
11.0
10.3
14.0
10.5
14.9
10.3
14.0
10.5
14.9
10.3
14.0
10.5
14.9
10.3
14.0
10.5
14.9
10.3
14.0
10.5
14.9
10.3
14.0
10.5
14.9
10.3
14.0
10.5
14.9
10.3
14.0
10.5
14.9
10.3
14.0
10.5
14.9
10.3
14.0
10.5
14.9
10.3
14.0
10.5
14.9
10.3
14.0
10.5
14.6
10.3
14.0
10.5
14.4
10.3
14.0
10.5
14.2
10.3
13.8
10.4
13.9
10.3
13.5
10.3
13.7
TC: Total capacity;kW – SHC: Sensible capacity;kW
20.0WB
22.0WB
28.0DB
30.0DB
SHC
TC
SHC
TC
8.7
13.4
9.0
14.2
8.7
13.4
9.0
14.0
8.7
13.4
9.0
13.8
8.7
13.3
9.0
13.6
8.7
13.2
8.9
13.4
8.7
13.0
8.8
13.2
8.7
12.9
8.8
13.2
8.7
12.7
8.7
13.0
8.7
12.5
8.6
12.8
8.7
12.3
8.5
12.6
8.6
12.2
8.4
12.4
8.5
12.0
8.3
12.2
8.5
11.8
8.2
12.1
8.4
11.6
8.1
11.9
8.3
11.4
8.0
11.7
8.2
11.2
7.9
11.5
10.8
16.7
11.1
17.7
10.8
16.7
11.1
17.5
10.8
16.7
11.1
17.2
10.8
16.7
11.1
17.0
10.8
16.4
11.0
16.8
10.8
16.2
10.9
16.6
10.8
16.1
10.9
16.4
10.8
15.9
10.8
16.2
10.8
15.6
10.6
16.0
10.8
15.4
10.5
15.8
10.7
15.2
10.4
15.5
10.6
15.0
10.3
15.3
10.5
14.7
10.2
15.1
10.4
14.5
10.1
14.9
10.3
14.3
10.0
14.6
10.2
14.1
9.9
14.4
24.0WB
32.0DB
SHC
8.9
8.9
8.8
8.7
8.6
8.5
8.5
8.4
8.3
8.2
8.1
8.0
7.9
7.8
7.7
7.6
11.1
11.0
10.9
10.8
10.7
10.6
10.5
10.4
10.3
10.2
10.1
10.0
9.8
9.7
9.6
9.5
CA08A050
137