IMPORTANT USER INFORMATION
Dear Customer, please read through these operating instructions carefully. Above all
please observe the safety instructions on the first few pages of this booklet. Please
keep these operating instructions for later reference and pass them on to any subsequent
owner of this cooker hood.
The safety standards of Electrolux electrical appliances are in keeping with the
recognised rules of technology and the law governing the safety of appliances. Prior
to operating this cooker hood please familiarize yourself with the following safety
instructions:
For the installer
• When used as an extractor unit, the hood must be fitted with a 125mm diameter hose.
Attention: The hose is not supplied and must be purchased seperately.
• When installing the hood, observe the following minimum distances from the cooking
top:
Electric cookers
Gas cookers
The hood can be installed above these heights but for optimum performance it should be
installed at the distance quoted for the appropriate heat source.
• The national standard on fuel-burning systems specifies a maximum depression of 0.04
mbar in such rooms.
• The air outlet must not be connected to chimney flues or combustion gas ducts. The air
outlet must under no circumstances be connected to ventilation ducts for rooms in which
fuel-burning appliances are installed.
• The air outlet installation must comply with the regulations laid down by the relevant local
authorities.
• When the unit is used in extraction mode, a sufficiently large ventilation hole must be
provided, with dimensions that are approximately the same as the outlet hole.
• National and regional building regulations impose a number of restrictions on using hoods
and fuel-burning appliances connected to a chimney, such as coal or oil room heaters and
gas fires, in the same room.
• Hoods can only be used safely with appliances connected to a chimney if the room and/or
flat (air/environment combination) is ventilated from outside using a suitable ventilation
hole approximately 500-600cm² large to avoid the possibility of a depression being created
during operation of the hood.
• If you have any doubts, contact the relevant controlling authority or building inspector's
office.
• Since the rule for rooms with fuel burning appliances is "outlet hole of the same size as
the ventilation hole", a hole of 500-600cm², which is to say a larger hole, could reduce the
performance of the extractor hood.
• If the hood is used in its recirculation mode, it will operate simply and safely in the above
conditions without the need for any of the aforementioned measures.
• When the hood is used in its extraction mode, the following rules must be followed to obtain
optimal operation:
- Short and straight outlet hose
- Keep bends in outlet hose to a minimum
- Never install the hoses with an acute angle, they must always follow a gentle curve
- Keep the hose as large as possible (preferably the same diameter as the outlet hole)
- The length should be no more than:
3 meters with one 90º bend
2 meters with two 90º bends