3.5) Operation of the digital controller

Sous Tension – Alive
Arret – stop Marche – run Step 2 Secure
Factory settings – Step 1 – 80degC; Step 2 – 75degC
1 – digital numbers or message
2 – touch settings
3 – touch raise settings
4 – touch lower settings
5 – controller action
Light out – none, light on – in action
6 - controller reading
7 - error/lockout
Adjusting temperatures
a) SET 1 – step 1
b) SET 1 is always higher than SET 2
c) Minimum temperature setting +20degC
d) Maximum temperature setting +99degC
e) Set SET 1 to 3degC below factory setting and allow 3 minutes to reach the setting
f) Set SET 2 to 2degC below factory setting and allow 3 minutes to reach the setting
g) Replace SET 1 and SET 2 at the factory settings
AFTER THE WAITING PERIOD OF 3 MINUTES
A) Touch (2) SET 1 for 5 seconds – reading (6) shows
B) Make adjustments to (6), touching (3) and (4)
C) Confirm the setting SET 1 by touching (2)
Indicator (1) flashes, indicating that Step One is confirmed
Setting (6) fades out and after several seconds, the actual temperature is shown
D) Touch (2) SET 2 for 5 seconds – reading (6) shows
E) Make adjustments to (6), touching (3) and (4)
F) Confirm the setting SET 2 by touching (2)
Indicator (1) flashes, indicating that Step One is confirmed
Setting (6) fades out and after several seconds, the actual temperature is shown
Step 1
Limit thermostat 110degC
SET 2 – step 2