MAINTENANCE
The water purifier is designed to operate with a minimal amount of maintenance, providing the water quality does not
exceed maximum concentration levels, see "Water Quality" in the "Product Application" section. Ordinary
maintenance consists of;
• Lamp replacement is recommended every 10,000 hours of operation, approximately 12 months of continuous service.
• Cleaning of the quartz sleeve, when conditions warrant.
• Always disconnect the water supply and completely drain the water purifier if it will be subjected to temperatures
below freezing, for extended periods of time.
I
NSPECTION
1. Regularly inspect the water purifier to ensure that the germicidal lamp is still in operation.
• On purifiers not equipped with the Ultraviolet Monitor, lamp operation can be verified by a visible glow through
the translucent sight port. This provides an indication of lamp operation and does not indicate the level of
ultraviolet intensity or transmission through the water.
• On purifiers so equipped, the Guardian™ Ultraviolet Monitor provides visual indication of the ultraviolet intensity
through the quartz sleeve and water in the purifier chamber.
2. To ensure proper operation of the water purifier, regular biological testing should be performed on a schedule
recommended by local public health authorities, or at minimum; at installation, quarterly for the first year of
service and annually, at lamp replacement, for the life of the water purifier.
D
M
ISPOSAL OF
Germicidal ultraviolet lamps, like standard fluorescent lamps contain small amounts of mercury. Mercury added
lamps should not be placed in the trash. Dispose of properly.
For further information regarding the disposal and recycling of lamps containing mercury, along with Federal and State
requirements visit http://www.lamprecycle.org. Product Data Sheets for germicidal ultraviolet lamps can be found in the
"PDF Library for Ster-L-Ray
Q
S
UARTZ
LEEVE
Step 1 - Lift wiper clip up
8
A
L
ERCURY
DDED
AMPS
TM
Germicidal Ultraviolet Lamps" section of http://www.ultraviolet.com.
C
LEANING USING
Figure 4 - Quartz Sleeve Cleaning
Step 2 - Gently pull wiper knob out
W
M
IPER
ECHANISM
Routine cleaning of the quartz sleeve is easily accomplished,
using the dual action wiper mechanism.
1.
Lift wiper clip up and away from wiper rod.
2.
Grasp wiper knob and gently pull out, away, from the
purifier until it reaches its stop
3.
Push wiper back in, toward the purifier until it reaches
its second stop.
4.
Repeat steps 2 and 3 as necessary.
5.
Holding wiper in place, return wiper clip and snap over
wiper rod, in front of the wiper lock spacer.
Step 3 - Push wiper back in