fore use Failure to do so may lead to electrical shock, or a fire
hazard
CLEAN EXTERIOR: Clean the exterior plastic housing with
mild detergent and water. To restore shine, clean with a strip-
ping cleaner such as 409, then spray with Armor-All or other
vinyl cleaner-protectant.
EXTERIOR INSPECTION: Evaluate exterior components and
make sure that they are properly installed. Repair or replace
missing components as required Listen to the unit for abnor-
mal sounds and repair as needed

SPECIFICATIONS

116-volt model
Air volume
Static pressure
7.3" water lift

TROUBLESHOOTING

Solutions fall into two categories listed in the third column. Field Solutions (FS) are those procedures that can be handled by the technician
in the field. Others solutions should be handled by a repair technician and are listed as Authorized Service Technician (AST).
WARNING: All the service procedures below should be executed with power off, i.e. unplugged,
PROBLEM
Motor won't
t Switch not turned on
run.
2. No power at outlet
3. Switch is broken
4. Loose wiring
1. Severe jolt has caused wheel to rub
Motor runs but
wheel makes a
against housing
scraping noise.
141 kinderkarnack Rd. Park Ridge. NJ 07656 Tel. 201-782-1782 Fax. 201-782-1783 Web: vvww.amgaircorn Email: [email protected]
230-volt model
780 cfm
1,150 cmh
13 cm water lift
CAUSE
Ric filatko
Air Marketing Group LLC
Amps
Size (LxWx1-1)
Weight
Motor
Wheel speed
Wheel size
Cord length
Specifications are subject to change without notice.
Some values may be approximate.
Caution
FS
1
Turn switch to appropriate speed
FS
2. Check outlet with receptacle tester
AST
3. Call factory for replacement switch
AST
4. Check wiring and tighten as needed
1. Call Dri-Eaz Service Department for advice.
AST
Geo
(LC
9.8 amps
16" x 21 x 17"
40 x 52 x 44 cm
35 lb
1 hp
3,450 rpm
10.625' x 2" radial
27 x 5 cm radial
25 ft
SOLUTION
4.9 amps
16 kg
0.75 kw
2,875 rpm
7.6 meters