imer
Treatment Time
•
Displayed in hours : Minutes and indicates how much time is left until treatment is concluded. During the treatment, the
display counts down until treatment is complete and the lamps switch off. The time display will then restore to last setting.
hour buttons
•
Selecting up and down arrows sets treatment from 0 to 24 hours.
Minute buttons
•
Selecting up and down arrows sets treatment from 0 to 59 minutes.
Power indicator
•
Red Power indicator light glows red when power is applied.
•
Pulses after start button has been pushed to show a warning during the 3-minute exit time. Pulses again during the last minute
of the treatment time.
Start button
•
Press to start, pause or to restart the treatment time.
Automatic Exit Timer
Provides 3-minute delay after "Start" button has been pushed, to allow the operator to exit the treatment area.
•
Flashes Red Power indicator during the 3-minute delay and during the last minute of the treatment time.
•
•
Provides a pulsing audio alarm during the 3-minute delay and the last minute of the treatment time.
t
esting
Wear personal protection equipment; Gloves, long sleeve shirt with no gaps between cuffs and gloves, and
an ultraviolet blocking face shield MuSt be worn to cover and protect eyes and all exposed skin.
1.
Although the cover must be fitted before testing the Sanidyne
as an extra precaution.
2.
Connect the power cord, Plug into appropriate power source.
3.
The Power indicator should light.
4.
use the Hours and minutes buttons to set the treatment time to display a short time, such as 00:02 (2 minutes).
5.
Press the Start button. The Power lamp will flash an exit warning and the audible alarm will beep.
Press the Start button again to pause again the exit warning. Confirm that the flashing and beeping stops.
6.
Press the Start button again to restart the exit time.
7.
8.
At the end of the three minute exit time, the audible alarm will stop and the POWER indicator light will stop flashing.
9.
The germicidal lamps should then switch on for the time set in the digital treatment time display.
10. Ensure that all four lamps are lit through the sight ports in cover and that lamps remain on for the time set
on the digital display.
11. The pulsing audible alarm and flashing light will start again at the start of the last remaining minute of the treatment time and
will stop when the treatment time ends.
The power plug may be removed when treatment is finished.
Keep the protective storage cover in place when the Sanidyne
Figure 2 - Timer Configuration
, the operator must also put on the safety face shield
®
is not in use.
®
7