Press the START button again to pause the exit warning. Confirm that the beeping stops.
6.
7.
Press the START button again to restart the exit time.
At the end of the 1-minute, 30-second exit time, the audible alarm will stop and the POWER indicator light will start flashing.
8.
9.
The STER-L-RAY
10. Ensure that all eight STER-L-RAY
for the time set on the digital display.
11. The power plug may be removed when treatment is finished.
12. Keep the protective storage cover in place when the Sanidyne
D
t
etermining
reatment
The
Sanidyne
should this unit be permitted to operate with humans, plants or animals present in the Operation Area. Consult our UV
Application Specialists if you have any questions or need help with the Sanidyne
1.
The fixture should be located in the approximate center of the room and target surfaces must be directly exposed to the
ultraviolet rays. It is important to remove items from direct line of sight that would block or shield UV rays from striking target
surfaces. Depending on the configuration of the space, and what specific disinfection you are looking to achieve, it may be
advisable to operate the
2.
Measure the longest distance from the
Fixtures / Time (Minutes) shown on Figure 3 below.
3. For example, if the distance from your fixture measures 15 feet, find the 15 foot mark on the bar chart for each time range.
As the treatment time increase, dose increases. (NOTE: The number at the end of each bar is the expected dose for each time
increment in millijoules per square centimeter.)
4. If a greater dose is required, increase treatment time.
30
25
20
15
7.932
10
3.966
5
7.053
NOTE: Dose shown above is expressed as mJ/cm
10
Germicidal Lamps should then switch on for the time set in the digital treatment time display.
®
Germicidal Lamps are lit through the sight ports in top cover and that lamps remain on
®
t
ime
is intended for use in UNOCCUPIED AREAS ONLY. Under no circumstances
Prime
®
on each side of large fixed objects (like a bed, or table, etc).
Sanidyne
Prime
®
Sanidyne
Figure 3 – Recommended Treatment Time for Room Sizes -
23.796
19.830
15.864
28.212
11.898
21.159
14.106
31.746
15.873
Prime is not in use
®
to the farthest wall. Use this length to compare to the Distance From
Prime
®
42.318
35.265
47.619
Dose (mJ/cm
2
(millijoule per square centimeter).
2
Prime.
®
®
Sanidyne
Prime
79.365
63.492
Distance From Fixture
15.0 Foot
10.0 Foot
)
95.238
20.0 Foot