Electrolux RH36PC60GSB Manuale d'uso e manutenzione - Pagina 7

Sfoglia online o scarica il pdf Manuale d'uso e manutenzione per Cappa di ventilazione Electrolux RH36PC60GSB. Electrolux RH36PC60GSB 42. 36" and 42" island range hood
Anche per Electrolux RH36PC60GSB: Manuale di installazione, uso e cura (21 pagine)

Electrolux RH36PC60GSB Manuale d'uso e manutenzione
Installing the hood
Installing the hood
For the most eficient air flow exhaust, use a
straight run or as few elbows as possible.
Vent unit to outside of building and recirculating.
On avarage 2 to 3 hours are necessary to com-
plete installation (without considering cut to be
done on wall and or on cabinet, installation of
ducts, conduit and electrical connections to the
mains).
The hood is fitted with Screws and Drywall
Anchors suitable for most surfaces, consult a
Qualified Installer, check if they perfectly fit with
your cabinet/wall.
Typical installation
Min installation height from the range top to the
bottom of the hood is 30" if a gas range is used
or 24" to 30" if an electric range is used.
These hoods are not recommended to be used
over indoor grills.
The hood may be installed vented to the outdoors, or
it can be installed for recirculating operation
(recirculating accessories not supplied with the
hood).
This hood can be installed over any electric and
gas cooktop/range.
This hood must not be installed over any
professional cooktop / range.
Do not use flex ducting.