Atlas Copco 8431017045 Istruzioni per il prodotto - Pagina 8
Sfoglia online o scarica il pdf Istruzioni per il prodotto per Utensile elettrico Atlas Copco 8431017045. Atlas Copco 8431017045 12.
Service
Service
Preventing ESD problems
The components inside the tool and controller are sensitive to electrostatic dis-
charge. To avoid future malfunction, make sure that service and maintenance is
carried out in an ESD approved work environment. The figure below shows an
example of an appropriate service work station.
Maintenance instructions
Service recommendations
The recommended conditions for the tool are:
8 hours/day and 3000 tightening/day
20 days/month and 60,000 tightening/month
Roller
Washer
Gear case
Gears
Gear complete
Table 1: Maintenance table
Perform maintenance or overhauling more frequently if the tool is used at high
torque, higher cycle rate than recommended or if self tapping screws and longer
tightening times are used.
Service instructions
Clean all parts and replace any defective or worn out parts during overhaul or
maintenance.
8
EN
Maintenance
After 500,000 tightening
After 500,000 tightening
After 500,000 tightening
After 500,000 tightening
X
© Atlas Copco Industrial Technique AB - 9836 8213 01
Replacement
After 1,000,000 tightening
After 1,000,000 tightening
X
X
After 1,000,000 tightening
EBL55-RE