Airtecnics Kleenbox 46/46 Manuale di installazione, funzionamento e manutenzione - Pagina 12
Sfoglia online o scarica il pdf Manuale di installazione, funzionamento e manutenzione per Pulitore d'aria Airtecnics Kleenbox 46/46. Airtecnics Kleenbox 46/46 16. Hepa filtration box
The G4 and F7 filters can be removed by pulling them once the service panel is removed:
G4 Filter
F7 Filter
After removing the G4 and F7 filters, there is enough space to take off the H14 filter. This one is fixed to the
housing by four wing nuts that should be untighten before remove the filter:
HEPA H14 Filter
To place the filters inside the equipment, follow the same steps but in reverse order: first, HEPA H14 filter,
secondly, F7 filter; and, the last one, G4 filter. Finally, close the service panel and close it using the key.
12