Atlas Copco 2000-2/SMF2 Istruzioni per la riparazione - Pagina 4

Sfoglia online o scarica il pdf Istruzioni per la riparazione per Trapano Atlas Copco 2000-2/SMF2. Atlas Copco 2000-2/SMF2 8.

Atlas Copco 2000-2/SMF2 Istruzioni per la riparazione
1
Dismantling the
Unscrew and remove the service cover (2).
handle shells
2
Loosen the screws of the cable clip (5),
remove it and lay bare the power supply
lead.
3
Loosen the connectors (4).
4
Unscrew and remove the housing (3).
1
Dismantling the
Lever off the brush holder insulation (1)
motor
and the brush holders (3) together with the
carbon brushes (2).
2
Only applicable for PN 2000 SMF2:
Remove the switch (6) completely with the
torque pre-setting dial and the torque
switch.
3
Dismantle the switch.
4
Branch off the cords.
5
Remove the armature (4) together with the
field (5) from the housing.