CARTRIDGE & RO MEMBRANE CHANGE INSTRUCTIONS
Pre-filter Cartridge (Replace every 12 months)
1. Close tank shut-off.
2. Turn used pre-filter cartridge 1/4 turn to the left.
3. Pull down on cartridge.
4. Discard used cartridge.
5. Remove red cap from new cartridge and moisten the o-ring with water.
6. Insert new cartridge into the filter head.
7. Turn new cartridge 1/4 turn to the right.
8. Open tank shut-off and inlet valves.
9. Check for leaks.
10. Flush cartridge per SYSTEM START UP INSTRUCTIONS on previous page.
Membrane (Replace every 24 months)
1. Close tank shut-off and inlet valves.
2. Turn used RO membrane cartridge 1/4 turn to the left.
3. Pull down on cartridge.
4. Remove the tubing from the fitting (refer to Figure 4).
5. Discard used cartridge.
6. Remove red cap from new membrane and moisten the o-ring with water.
7. Remove the plug from the RO membrane.
8. Insert the tubing from Step 4 into the new RO membrane. Ensure the blue flow control is
properly pushed into
the tubing.
9. Insert new cartridge into the filter head. Be sure that the ears on the cartridge line up
with the spaces in the head.
10. Turn new cartridge 1/4 turn to the right.
11. Repeat steps 5-12 from System start-up.
Remove the tubing from
the fitting before completely
removing the RO membrane
Figure 4
7