Bose 2060 Manuale dell'installatore - Pagina 30

Sfoglia online o scarica il pdf Manuale dell'installatore per Amplificatore Bose 2060. Bose 2060 40. Commercial power amplifiers

Bose 2060 Manuale dell'installatore
5.0 Installation
5.3.6 Bridged mono operation
The STEREO/MONO switch is located behind slot #2 of the standard input module (see
Figure 31). For bridged-mono operation, move the STEREO/MONO switch all the way to the
right to the BRIDGED setting. Connect the input signal to CH 2 input (CH 1 input becomes
disabled).
Outputs:
Jumper the Commons (COM) on both CH 1 and CH 2. Next, connect the negative (–) to the
desired setting CH 1 output and positive (+) to the same setting on the CH 2 output.
When connected in this way, each channel "sees" half the impedance of the speaker
connected between them.
Note: Be sure to set both input level controls to exactly the same setting for equal power
distribution per channel.
In high-impedance bridged-mono operation, the amplifier will yield the following results:
Channel 1
Channel 2
25V
+
25V
35V
+
35V
50V
+
50V
70V
+
70V
100V
+
100V
Jumper
CAUTION
AVIS
RISK OF ELECTRICAL SHOCK
RISQUE DE CHOC ELECTRIQUE
DO NOT OPEN COVER,
NE PAS OUVRIR CE CARTER,
AUTHORIZED PERSONNEL
RESERVE AU PERSONNEL
ONLY.
AUTORISE.
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK DO NOT
EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE
This device complies with part 15 of the FCC rules. Operation is subject to the following
conditions: (1) This device may not cause harmful interference and (2) this device must
accept any interference received, including interference which may cause undesired operation.
Complies with Canadian ICES-003 Class A specifications.
120VAC, 4.6A max.
60 Hz
600W
SERIAL No.:
®
Model 2150
D.O.M.:
BOSE CORPORATION
FRAMINGHAM, MA 01701-9168 U.S.A.
MADE IN U.S.A. OF DOMESTIC AND FOREIGN COMPONENTS.
In low impedance bridged-mono operation, the amplifier will yield the following results:
Channel 1
Channel 2
4Ω
+
4Ω
8Ω
+
8Ω
Jumper
CAUTION
AVIS
RISK OF ELECTRICAL SHOCK
RISQUE DE CHOC ELECTRIQUE
DO NOT OPEN COVER,
NE PAS OUVRIR CE CARTER,
AUTHORIZED PERSONNEL
RESERVE AU PERSONNEL
ONLY.
AUTORISE.
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK DO NOT
EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE
This device complies with part 15 of the FCC rules. Operation is subject to the following
conditions: (1) This device may not cause harmful interference and (2) this device must
accept any interference received, including interference which may cause undesired operation.
Complies with Canadian ICES-003 Class A specifications.
120VAC, 4.6A max.
60 Hz
600W
®
SERIAL No.:
Model 2150
D.O.M.:
BOSE CORPORATION
FRAMINGHAM, MA 01701-9168 U.S.A.
MADE IN U.S.A. OF DOMESTIC AND FOREIGN COMPONENTS.
30
Bridged Operation
=
50V
=
70V
=
100V
=
140V
=
200V
70V line
+ 35V
- 35V
Use Class 2 Wiring
CH 2
CH 1
For bridged operation.
Consult user manual.
WARNING
RISK OF HAZARDOUS
ENERGY! MAKE PROPER
SPEAKER CONNECTIONS.
SEE OPERATING
MANUAL BEFORE USING.
AVERTISSEMENT
SEQUENCE
REMOTE LEVEL
ENERGIE ELECTRIQUE
DANGEREU SE. VOIR
LANOTICE
DE FONCTIONNEMENT.
CH 2
CH 1
SND RCV
COM CH2 CH1 +5V
FX CH 1
FX CH 2
J20018292
SEND
RECV
SEND
RECV
+
+
+
+
PN# 1234567
Bridged Operation
=
8Ω
=
16Ω
8Ω line
+ 4Ω
- 4Ω
Use Class 2 Wiring
CH 2
CH 1
For bridged operation.
Consult user manual.
WARNING
RISK OF HAZARDOUS
ENERGY! MAKE PROPER
SPEAKER CONNECTIONS.
SEE OPERATING
MANUAL BEFORE USING.
AVERTISSEMENT
SEQUENCE
REMOTE LEVEL
ENERGIE ELECTRIQUE
DANGEREU SE. VOIR
LANOTICE
DE FONCTIONNEMENT.
CH 2
CH 1
SND RCV
COM CH2 CH1 +5V
J20018292
FX CH 1
FX CH 2
RECV
SEND
RECV
SEND
+
+
+
+
PN# 1234567
INPUT IMPEDANCE 25K OHMS EACH LEG TO GROUND (TOTAL 50K OHMS BALANCED)
SEND
RECEIVE
PUSH
PUSH
INPUT CH 2
INPUT CH 1
SEQUENCE
2
1
2
EQUALIZATION
ON
CH1
3
+
2
1
CH2
3
CH2
EQ. OUT
CH1
INPUT IMPEDANCE 25K OHMS EACH LEG TO GROUND (TOTAL 50K OHMS BALANCED)
SEND
RECEIVE
PUSH
PUSH
INPUT CH 2
INPUT CH 1
SEQUENCE
2
1
EQUALIZATION
2
ON
CH1
3
+
2
1
CH2
3
CH2
EQ. OUT
CH1
November 19, 2001
Figure 34
High impedance operation at 70V
1
3
Figure 35
Low impedance operation at 8Ω
1
3
AM259107_00_V.pdf