Sfoglia online o scarica il pdf Manuale di riferimento per l'utente per Telecomando Daikin ALTHERMA. Daikin ALTHERMA 20. Low temperature split, eabh16da6v, eabh16da9w, eabx16da6v, eabx16da9w, eavh16s18da6v(g), eavh16s23da6v(g), eavh16s18da9w(g), eavh16s23da9w(g), eavx16s18da6v (g), eavx16s23da6v(g), eavx16s18da9w(g), eavx16s23da9w(g)
Anche per Daikin ALTHERMA: Manuale rapido (4 pagine), Manuale di installazione (9 pagine), Manuale d'uso (5 pagine)
4 Operation
Calculation of the electricity price:
Electricity price=Actual electricity price+Incentive/kWh
Electricity price=12.49+5
Electricity price=17.49
Price
Gas: 4.08 /kWh
Electricity: 12.49 /kWh
4.7.3
Using and programming schedules
About schedules
Depending on your system layout and installer configuration,
schedules for multiple controls may be available.
You can:
▪ Select which schedules you currently want to use.
▪ Program your own schedules if the predefined schedules are not
satisfactory. The actions you can program are control specific.
Possible scheduling screens
Name and location
[1.2] Room > Heating
Program the desired room temperature
schedule
in heating mode.
[1.3] Room > Cooling
Program the desired room temperature
schedule
in cooling mode.
[2.2] Main zone > Heating
Program the desired leaving water
schedule
temperature for the main zone in
heating mode.
[2.3] Main zone > Cooling
Program the desired leaving water
schedule
temperature for the main zone in
cooling mode.
[3.2] Additional zone >
Program the desired leaving water
Heating schedule
temperature for the additional zone in
heating mode.
[3.3] Additional zone >
Program the desired leaving water
Cooling schedule
temperature for the additional zone in
cooling mode.
[4.2] Space heating/
See
cooling > Operation mode
mode" on
schedule
[5.5] Tank > Schedule
Program the domestic hot water tank
temperature for your normal domestic
hot water needs:
▪ Comfort
▪ Eco
▪ Stop
[7.4.2] User settings >
Program when the unit has to use which
Quiet > Schedule
quiet mode level:
▪ Off
▪ Quiet
▪ More quiet
▪ Most quiet
[7.5.4] User settings >
Program when a certain electricity tariff
Electricity price >
is valid.
Schedule
Example of programming a schedule
See
"4.7.4 Schedule screen: Example" on
User reference guide
12
Value in breadcrumb
[7.6]=8.6
[7.5.1]=17
Usage
"4.4.2 Setting the space operation
page 7.
page 12.
4.7.4
Schedule screen: Example
This example shows how to set a room temperature schedule in
heating mode for the main zone.
INFORMATION
The procedures to program other schedules are similar.
To program the schedule
Example: You want to program the following schedule:
User defined 1
Mon
Tue
Wed
Thu
Fri
Sat
Sun
Prerequisite: The room temperature schedule is only available if
room thermostat control is active. If leaving water temperature
control is active, you can program the main zone schedule instead.
1 Go to the schedule.
2 Clear the contents of the schedule (optional).
3 Program the schedule for Monday.
4 Copy the schedule to the other weekdays.
5 Program the schedule for Saturday and copy it to Sunday.
6 Give the schedule a name.
To go to the schedule:
1 Go to [1.1]: Room > Schedule.
2 Set scheduling to Yes.
3 Go to [1.2]: Room > Heating schedule.
To clear the contents of the schedule:
1 Select the name of the current schedule.
User defined 1
Mon
Tue
Wed
Thu
Fri
Sat
Sun
2 Select Delete.
Delete
Edit
3 Select OK to confirm.
To program the schedule for Monday:
1 Select Monday.
User defined 1
Mon
Tue
Wed
Thu
Fri
Sat
Sun
EABH/X16DA+9W + EAVH/X16S18+23DA6V+9W
Daikin Altherma – Low temperature split
4P556071-1 – 2018.10