DROPSA 3417000 Series Manuale - Pagina 5
Sfoglia online o scarica il pdf Manuale per Pompa dell'acqua DROPSA 3417000 Series. DROPSA 3417000 Series 9. Micro-elettric pump
8. OPERATING HAZARDS
The micro pump has no particular contraindications except for the following points:
•
Contact with fluid for breaking / opening of adduction piping. -> The operator must be equipped appropriate
individual protective devices DPI.
•
Unsuitable postures. -> See paragraph 9.2.
• contact with oil -> see instructions for using appropriate individual protective devices DPI;
• Use of an inappropriate lubricant -> fluid characteristics indicated both on the pump and in the manual (if in doubt
consult our Technical Office);
Fluids
Lubricant with abrasive additives
Lubricant with silicon additives
Benzine – solvents – inflammable liquids
Corrosive products
Water
Food substances
9.
UNPACKING AND INSTALLING
9.1 UNPACKING
Once a suitable installation position has been identified, unpack the pump and prepare for installation. It is important to
inspect the pump to ensure that there has been no damage during transportation. The packaging material used does not
require any special disposal procedures. You should refer to you regional requirements.
9.2 PUMP INSTALLATION
There are no installation operations of pump.
Allow sufficient space for install with 100mm clear space around the perimeter of the pump.
Mount the pump at "eye level" to avoid any risk of postural problems. There are two fixing holes on the plate, with
different distances depending on the 1 Lt and 1.7 Lt version.
Afterwards is necessary connect he pump to the machine with hydraulic connection, refill the reservoir and connect to
the control panel.
Empty the reservoir during the disassembly phase.
Disconnect electrical and hydraulic parts.
9.3 HYDRAULIC CONNECTIONS
Only connection is to be made from the pump to the lubrication point or the metering valves.
9.4 ELECTRICAL CONNECTIONS
Before carrying out any wiring, ensure that the correct power supply is available. Refer to the identification label on the
Pump. In order to avoid dangers of electric shock it is important to remove all power before installation or maintenance.
All electrical components and control devices must be grounded. Make sure that the ground wire is correctly connected.
For safety reasons, the earth conductor should be approximately 100 mm longer than the phase conductors. In case of
accidental cable detachment, the ground terminal must be the last to come off.
In order to prevent dangers of electric shocks due to direct or indirect contact with the energized parts, electrical power
supply line must be protected by a suitable magneto-thermal circuit breaker with an intervention threshold of 30mA and
1 millisecond minimum operating time.
Circuit breaker power must be = 10 kV and nominal power in In = 6 A.
N.B.: after all connections make sure that pipes and cables are appropriately fixed and protected from impacts.
6
UNACCEPTABLE FLUIDS
High consumption of contaminated parts
Jamming of the pump
Fire – explosion – damage to gaskets
Corrosion of the pump – injuries to persons
Pump oxidation
Contamination of these substances
Dangers