Explanation of heating operation
Defrost operation
As the frost on the coil of an outdoor unit increase,
heating effect decreases and the system goes into
DEFROST OPERATION.
The fan operation stops and the DEFROST lamp of
the indoor unit goes on.
After 6 to 8 minutes (maximum 10 minutes) of
DEFROST OPERATION, the system returns to
HEATING OPERATION.
Heating capacity and outdoor air temperature
Heating capacity drops as outdoor air temperature
lowers. If feeling cold, use another heater at the same
time as this air conditioner.
Hot air is circulated to warm the room. It will take
some time from when the air conditioner is first
started until the entire room becomes warm. The
internal fan automatically turns at low speed until the
air conditioner reaches a certain temperature on the
inside. In this situation, all you can do is wait.
If hot air accumulates on the ceiling and feet are left
feeling cold, it is recommended to use a circulator.
For details, contact the place of purchase.

Adjustment

For programming TEMPERATURE, FAN SPEED and
AIR FLOW DIRECTION, follow the procedure shown
below.
TEMPERATURE SETTING
Press
TEMPERATURE
program the setting temperature.
Each time this button is pressed, setting
temperature rises 1°C.
UP
Each time this button is pressed, setting
temperature lowers 1°C.
DOWN
In case of automatic operation
Each time this button is pressed, setting
temperature shifts to "H" side.
UP
Each time this button is pressed, setting
temperature shifts to "L" side.
DOWN
Setting temperature
The setting is impossible for fan operation
- The setting temperature range of the remote
controller is 16°C to 32°C.
BRC7F532+533F
Wireless remote controller kit
SETTING
button
and
°C
H
M
L
25
23
22
21
19
4PW29216-1
FAN SPEED CONTROL
Press FAN SPEED CONTROL button.
High or Low fan speed can be selected.
The micro computer may sometimes control the
fan speed in order to protect the unit.
AIR FLOW DIRECTION ADJUST
The movable limit of the flap is changeable. Contact
your dealer for details.
Up and down adjustment
Press the AIR FLOW DIRECTION ADJUST button to
select the air direction as shown below.
Display appears and the air flow
direction continuously varies.
(Automatic swing setting.)
Press AIR FLOW DIRECTION ADJUST
button to select the air direction of your
choice.
Display vanishes and the air flow
direction is fixed. (Fixed air flow
direction setting.)
Movement of the swing flap
For the following conditions, the micro computer
controls the air flow direction so it may be
different from the display.
Operation
mode
Heating
Operation
When starting operation.
conditions
When
higher than the set temperature.
At defrost operation. (The flaps
blow
blowing cold air directly on the
occupants of the room.)
NOTE
If you try cooling or programmed
drying, while the flaps are facing
downward, air flow direction may
change
nothing wrong with the equipment.
This serves to prevent dew formed
on parts in the air discharge outlet
from dripping.
Operation mode includes automatic
operation.
room
temperature
horizontally
to
avoid
unexpectedly.