DROPSA VIP4Air Series Manuale d'uso e manutenzione - Pagina 3

Sfoglia online o scarica il pdf Manuale d'uso e manutenzione per Sistemi di lubrificazione DROPSA VIP4Air Series. DROPSA VIP4Air Series 13. Minimal air/oil lubrication system
Anche per DROPSA VIP4Air Series: Manuale d'uso e manutenzione (16 pagine)

4. TECHNICAL SPECIFICATIONS

CHARACTERISTICS
Power supply voltage
Absorbed power
Air supply pressure
Output signals
Working temperature
Working humidity
Protection class
Admissible lubricants
Oil viscosity at working temp.
Conservation temperature
WARNING: DO NOT supply the machine with voltages or pressures other than those indicated on the specification plate.
5. DESCRIPTION OF COMPONENTS
Central VIP4Air Unit
The central unit of the lubrication system is composed of the three elements:
a Tank, made of transparent plastic material, compatible with lubricants on the market.
an air control system composed of a pressure regulator, applied laterally, and a solenoid valve, which can block the air flow.
the VIP4Air panel manages and controls the entire lubrication process: the time intervals, the lubrication flow rate, the air
pressure and the oil level. In addition it provides for priming cycles (air venting).
Pneumatic Mini-pump
The mini-pumps employed are particularly small and are installed on the mixer bases. They can be fitted with a range of spacers
which serve to vary the flow rate. The following table details how to recognize these and indicates the relative part numbers. To
change the spacers proceed as follows:
1. Unscrew and remove the brass cap (A).
2. Rotate shaft (B) until the hole (C) aligns with the relative slot.
3. Insert a Ø2 mm tommy bar in hole (C).
4. Unscrew hex. nut (D) using a 5,5 mm spanner.
5. Slide off the spacer (E) and replace it with the required one.
6. Replace and fully tighten nut (D), remove the tommy bar and replace cap (A).
N° OF NOTCHES
FLOW RATE
(mm
1
3
4
SPACER
3
/cycle)
PART NUMBER
30
3233188
15
3233191
7
3233193
VIP4Air lubrication panel
24 V dc
110 V ac
10 W
5 - 8 bar
Remote alarm contact: max. 250 V 1 A NO/NC
-5 - +55 °C
90% max.
IP-44
Oil
32 - 220 cSt
-20 - +65 °C
Notches
3