DROPSA 1525731 Manuale d'uso e manutenzione - Pagina 8
Sfoglia online o scarica il pdf Manuale d'uso e manutenzione per Strumenti di misura DROPSA 1525731. DROPSA 1525731 8. Volumetric flow meter for controlling the flow of liquids
15. PRECAUTIONS
No particular operating hazards characterize the FLOW MASTER, except for the following precautions:
•
The device is designed to operate with clean fluids not polluted by water. Presence of water can modify device reading.
•
Operator's contact with lubricant during maintenance tasks:
The operator must be provided with suitable personal protective clothing and devices
•
Use of incompatible lubricant:
Lubricants containing abrasive components
Lubricants containing silicon
Petrol – solvents – inflammable liquids
Corrosive products
Water
Food Products
8
FLUIDS EXPLICITY NOT ALLOWED
Fluids
Premature wear of pump
Pump failure
Fire – explosion –seal damage
Pump damage - danger to persons
Pump oxidization
Contamination of the product
.
Dangers