Step 5: Start pump, watch pressure
gauge and turn (See figure
6 ref. no. 2) using 3mm hex
clockwise until recommended/
rated pressure is obtained. Line
pressure will be approximately
200 psi less then actual head
pressure. DO NOT set line
pressure to rated.
Step 6: Release trigger and make sure
there is minimal spike (200-300
psi) (Repeat this step two or
three times).
Step 7: Tighten nut (See figure 4 ref.
no. 3) down against (See figure
6 ref. no. 4).
Step 8: Replace black cap (See figure 6
ref. no. 46)
NOTE: Now pressure can be decreased
by turning black knob counterclockwise,
but the pressure cannot be increased
to a rating higher than was set. We
recommend this procedure be done by
a qualified high pressure pump service
technician. Failure to properly adjust
can cause serious damage to equipment
and body.
Failure to use a pressure gauge
may cause the pump to be set
at a pressure that exceeds its
specifications. Resulting in injury
or pump damage.
Available from Allparts Equipment and Accessories - 1-877-475-5660 - www.allpartsinc.com
SJ & XJ Series Pumps
Service Pumps
Servicing the Valves
Discharge Valves:
Disassembly:
1.
Remove the valve cap
(See figure 7).
2.
Inspect the valve
cap O-ring for any
damage, replace if
necessary.
3.
Using a needle nose pliers
remove the valve. (See
figure 8)
4.
Use a small probe to
move the poppet up
and down to assure that
it is functioning properly.
5.
Inspect for any debris that may be
lodged between the poppet and
seat.
6.
Remove the valve seat O-ring and
inspect for any damage.
Assembly:
1.
Install the valve seat
O-ring squarely into
the bottom of the
manifold. (See figure
9)
2.
Insert the valve
assembly squarely into the
port pushing it into the O-
ring.
Figure 7