Safety Instructions and warnings

• To prevent injury or damage to the unit, the appliance should
be unpacked and set up by two people.
• In the event that the appliance is damaged on delivery, contact
the supplier immediately before connecting to the mains.
• To guarantee safe operation, ensure that the appliance is set up
and connected as described in these operating instructions.
• Disconnect the appliance from the mains if any fault occurs.
Pull out the plug, switch off or remove the fuse.
• When disconnecting the appliance, pull on the plug, not on
the cable.
• Any repairs and work on the appliance should only be carried
out by the customer service department, as unauthorised
work could prove highly dangerous for the user. The same
applies to changing the mains power cable.
• Do not allow naked flames or ignition sources to enter the
appliance. When transporting and cleaning the appliance,
ensure that the refrigerant circuit is not damaged. In the event
of damage, make sure that there are no ignition sources
nearby and keep the room well ventilated.
• Do not stand on the plinth, drawers or doors or use them to
support anything else.
• This appliance can be used by children of 8 years old and over,
and also by persons with restricted physical, sensory or mental
capacity or lack of experience and knowledge, if they are super-
vised or have been instructed on safe use of the appliance and
understand the resulting risks. Children must not be allowed to
play with the appliance. Cleaning and user maintenance must
not be carried out by children without supervision.
• Avoid prolonged skin contact with cold surfaces or chilled/
frozen food. This could cause pain, numbness and frostbite.
In the case of prolonged skin contact, protective measures
should be taken, e.g. gloves should be worn.
• Do not consume food which has been stored for too long, as
it could cause food poisoning.
• Do not store explosives or sprays using combustible propel-
lants such as butane, propane, pentane, etc. in the appliance.
Electrical components might cause leaking gas to ignite. You
may identify such sprays by the printed contents or a flame
symbol.
• Do not use electrical appliances inside the appliance.
• If you have a lockable appliance, do not keep the key near
the appliance or within reach of children.
• The appliance is designed for use in enclosed areas. Do
not operate the appliance outdoors or in areas where it is
exposed to water or damp conditions.
• The LED light strip illuminates the interior of the appliance. It is
not suitable for lighting a room.
6
• When transporting or operating the appliance at an altitude of
more than 1500 m above sea level, the glass pane in the door
can break due to the reduction in air pressure. Broken fragments
are sharp-edged and can cause serious injury.

Climate rating

The climate rating indicates the room temperature at which the
appliance may be operated in order to achieve full refrigeration
performance.
The climate rating is indicated on the type plate.
The position of the type plate is shown in the section entitled
Description of the appliance.
Climate rating
Room temperature
SN
+10 °C to +32 °C
N
+16 °C to +32 °C
ST
+16 °C to +38 °C
SN-ST
+10 °C to +38 °C
T
+16 °C to +43 °C
SN-T
+10 °C to +43 °C
Do not operate the appliance outside the
specified room temperature range.
Setting up
• Avoid positioning the appliance in direct sunlight or near
cookers, radiators and similar sources of heat.
• The floor on which the appliance stands should be horizontal and
level. Compensate for uneven floors with the adjustable feet.
Do not cover ventilation openings or grill..
• Standard EN 378 specifies that the room in
which you install your appliance must have a
volume of 1 m3 per 8 g of R 600a refrigerant
used in the appliance, so as to avoid the forma-
tion of inflammable gas/air mixtures in the room
where the appliance is located in the event of
a leak in the refrigerant circuit. The quantity of
refrigerant used in your appliance is indicated
on the type plate on the inside of the appliance.
• Always install the appliance directly against the wall.
• Place the appliance in its final position at the place of installation.
Extend the adjustable foot at the bottom
hinge bracket until it rests on the floor
and then make a further 90° turn.